GENESIS OF KOROTKOFF SOUNDS.

D CHUNGCHAROEN.   

Abstract

Keywords:  AUSCULTATION; BLOOD CIRCULATION; BRACHIAL ARTERY; CAROTID ARTERIES; DOGS; EXPERIMENTAL LAB STUDY; PHONOCARDIOGRAPHY

Mesh:

Year:  1964        PMID: 14193588     DOI: 10.1152/ajplegacy.1964.207.1.190

Source DB:  PubMed          Journal:  Am J Physiol        ISSN: 0002-9513


× No keyword cloud information.
  9 in total

1.  Spectral analysis of arterial sounds: a noninvasive method of studying arterial disease.

Authors:  R Gupta; J W Miller; A P Yoganathan; F E Udwadia; W H Corcoran; B M Kim
Journal:  Med Biol Eng       Date:  1975-09

2.  The Korotkoff sound.

Authors:  G M Drzewiecki; J Melbin; A Noordergraaf
Journal:  Ann Biomed Eng       Date:  1989       Impact factor: 3.934

3.  The relationship between vessel-wall elasticity and Korotkoff-sound frequency.

Authors:  B J Brookman; C Dalton; L A Geddes
Journal:  Med Biol Eng       Date:  1970-03

4.  Steady pressure flow relations in compressed arteries: possible origin of Korotkoff sounds.

Authors:  W A Conrad; D M McQueen; E L Yellin
Journal:  Med Biol Eng Comput       Date:  1980-07       Impact factor: 2.602

5.  Elevated nocturnal blood pressure assessed by ambulatory automatic monitoring during a stay at high altitude.

Authors:  J C Barthélémy; J R Lacour; F Roche; P Gosse; C Cristol; L Féasson; P Minini; A Geyssant
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1995

Review 6.  Korotkoff sounds dynamically reflect changes in cardiac function based on deep learning methods.

Authors:  Wenting Lin; Sixiang Jia; Yiwen Chen; Hanning Shi; Jianqiang Zhao; Zhe Li; Yiteng Wu; Hangpan Jiang; Qi Zhang; Wei Wang; Yayu Chen; Chao Feng; Shudong Xia
Journal:  Front Cardiovasc Med       Date:  2022-08-26

7.  Effect of respiration on Korotkoff sounds and oscillometric cuff pressure pulses during blood pressure measurement.

Authors:  Dingchang Zheng; Luigi Yuri Di Marco; Alan Murray
Journal:  Med Biol Eng Comput       Date:  2014-03-26       Impact factor: 2.602

8.  Comparison of systolic blood pressure values obtained by photoplethysmography and by Korotkoff sounds.

Authors:  Meir Nitzan; Yair Adar; Ellie Hoffman; Eran Shalom; Shlomo Engelberg; Iddo Z Ben-Dov; Michael Bursztyn
Journal:  Sensors (Basel)       Date:  2013-10-31       Impact factor: 3.576

9.  Effect of cuff positioning on the accuracy of blood pressure measurement with automated electronic blood pressure monitors.

Authors:  Ya Li; Fang Li; Yi Li; Xiaoran Cui; Jing Li; Hua Zhi; Weidong Wang; Yanyan Sun; Wei Cui
Journal:  J Clin Hypertens (Greenwich)       Date:  2020-06-09       Impact factor: 3.738