Literature DB >> 1416132

A comparison of methods for the detection of myocardial ischemia during noncardiac surgery: automated ST-segment analysis systems, electrocardiography, and transesophageal echocardiography.

J E Ellis1, M N Shah, J E Briller, M F Roizen, S Aronson, S B Feinstein.   

Abstract

Clinicians often fail to detect intraoperative ischemic electrocardiographic (ECG) changes when viewing oscilloscopes. Automated ST-segment monitors promise to increase the detection of such ECG changes. We investigated the capacity of two commercially available ST-segment monitors to detect intraoperative myocardial ischemia in patients at high risk for developing intraoperative myocardial ischemia during vascular and other noncardiac procedures. The ST-segment monitors were compared with two reference monitors: (a) printed eight-lead ECGs, as interpreted by a cardiologist, and (b) the presence of segmental wall motion abnormalities and thickening abnormalities detected by transesophageal echocardiography (TEE). We also examined the capacity of the printed ECG to diagnose myocardial ischemia when compared with TEE. We studied 44 patients who underwent TEE, printed multilead ECG, oscilloscope monitoring of leads V5 and II, and measurement of ST-segment deviation from the baseline using an automated Hewlett Packard ST-segment device. The sensitivities for the Hewlett Packard system were 40% for TEE-diagnosed myocardial ischemia and 75% for ECG-diagnosed ischemia. Comparison of the printed ECG with TEE revealed that ST-segment changes in the printed ECG, as analyzed by a cardiologist, were 25% sensitive and 62% specific for the detection of TEE-diagnosed myocardial ischemia. When T-wave inversions were added to ST-segment depression as a criterion for the diagnosis of myocardial ischemia by the printed ECG, the sensitivity of ECG for the detection of intraoperative myocardial ischemia, as determined by TEE, was 40% and specificity was 58%. Twenty-three of the 44 patients were simultaneously monitored in leads I, II, and V5 with an automated Marquette ST-segment monitor.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1992        PMID: 1416132     DOI: 10.1213/00000539-199211000-00020

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  5 in total

1.  Predicting ischaemic events in the perioperative period: in search of the perfect tool.

Authors:  J C Tardif; M Juneau
Journal:  Can J Anaesth       Date:  1996-10       Impact factor: 5.063

Review 2.  Intraoperative automated ST segment analysis: a reliable 'black box'?

Authors:  H Yang
Journal:  Can J Anaesth       Date:  1996-10       Impact factor: 5.063

3.  Crisis management during anaesthesia: myocardial ischaemia and infarction.

Authors:  G L Ludbrook; R K Webb; M Currie; L M Watterson
Journal:  Qual Saf Health Care       Date:  2005-06

Review 4.  Anaesthesia for coronary artery surgery--a plea for a goal-directed approach.

Authors:  R I Hall
Journal:  Can J Anaesth       Date:  1993-12       Impact factor: 5.063

5.  Spurious ST segment depression by automated ST segment analysis.

Authors:  S Brooker; E Lowenstein
Journal:  J Clin Monit       Date:  1995-05
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.