Literature DB >> 14160239

TECHNIQUE OF REFRIGERATED COIL PRESERVATION HAEMODIALYSIS WITH FEMORAL VENOUS CATHETERIZATION.

S SHALDON, H SILVA, S M ROSEN.   

Abstract

Keywords:  CATHETERIZATION; FEMORAL VEIN; HEPARIN; KIDNEY FAILURE, ACUTE; KIDNEY, ARTIFICIAL; REFRIGERATION

Mesh:

Substances:

Year:  1964        PMID: 14160239      PMCID: PMC1816024          DOI: 10.1136/bmj.2.5406.411

Source DB:  PubMed          Journal:  Br Med J        ISSN: 0007-1447


× No keyword cloud information.
  11 in total

1.  DAILY HAEMODIALYSIS IN "HYPERCATABOLIC" ACUTE RENAL FAILURE.

Authors:  H SILVA; J POMEROY; A I RAE; S M ROSEN; S SHALDON
Journal:  Br Med J       Date:  1964-08-15

2.  ALARM DEVICE WITH AUTOMATIC CUT-OUT FOR THE KOLFF TWIN-COLI KIDNEY.

Authors:  J BIENENSTOCK; S SHALDON
Journal:  Lancet       Date:  1963-10-19       Impact factor: 79.321

3.  Refrigerated femoral venous-venous haemodialysis with coil preservation for rehabilitation of terminal uraemic patients.

Authors:  S SHALDON; A I RAE; S M ROSEN; H SILVA; J OAKLEY
Journal:  Br Med J       Date:  1963-06-29

4.  Prophylactic hemodialysis in the treatment of acute renal failure.

Authors:  P E TESCHAN; C R BAXTER; T F O'BRIEN; J N FREYHOF; W H HALL
Journal:  Ann Intern Med       Date:  1960-11       Impact factor: 25.391

5.  Technic with parallel flow, straight tube blood dialyzer.

Authors:  A E MACNEILL; J E DOYLE; R ANTHONE; S ANTHONE
Journal:  N Y State J Med       Date:  1959-11-15

6.  Development of a parallel-flow artificial kidney in plastics.

Authors:  F KIIL
Journal:  Acta Chir Scand Suppl       Date:  1960

7.  A modification of the benzidine method for measurement of hemoglobin in plasma and urine.

Authors:  W H CROSBY; F W FURTH
Journal:  Blood       Date:  1956-04       Impact factor: 22.113

8.  Catheter replacement of the needle in percutaneous arteriography; a new technique.

Authors:  S I SELDINGER
Journal:  Acta radiol       Date:  1953-05       Impact factor: 1.990

9.  Eight months' experience with silastic-teflon bypass cannulas.

Authors:  W E QUINTON; D H DILLARD; J J COLE; B H SCRIBNER
Journal:  Trans Am Soc Artif Intern Organs       Date:  1962

10.  Artificial kidney function; kinetics of hemodialysis.

Authors:  A V WOLF; D G REMP; J E KILEY; G D CURRIE
Journal:  J Clin Invest       Date:  1951-10       Impact factor: 14.808

View more
  6 in total

1.  DAILY HAEMODIALYSIS IN "HYPERCATABOLIC" ACUTE RENAL FAILURE.

Authors:  H SILVA; J POMEROY; A I RAE; S M ROSEN; S SHALDON
Journal:  Br Med J       Date:  1964-08-15

2.  HAEMODIALYSIS DISEQUILIBRIUM.

Authors:  S M ROSEN; K O'CONNOR; S SHALDON
Journal:  Br Med J       Date:  1964-09-12

3.  Recirculating pump and the rupture of ultraflow twin coils.

Authors:  W Crossley; P J Tilley; D N Kerr
Journal:  Br Med J       Date:  1969-02-01

4.  Dialysance of molecules of different size in reused Kiil, Ab-Gambro, and Rhône-Poulenc dialysers.

Authors:  P Kramer; D Matthaei; J G Go; H J Tönnis; F Scheler
Journal:  Br Med J       Date:  1972-05-06

5.  Haemodialysis cost reduction by artificial kidney storage: a simple, effective technique for re-use of coil kidneys.

Authors:  R P Bell; J E Figueroa
Journal:  Br Med J       Date:  1970-03-28

6.  The artificial kidney in acute renal failure following surgery.

Authors:  A E Kulatilake
Journal:  Proc R Soc Med       Date:  1966-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.