Effects of chronic amiodarone therapy on defibrillation threshold.

W Jung1, M Manz, L Pizzulli, D Pfeiffer, B Lüderitz.   

Abstract

In a prospective and parallel, randomized study, the long-term stability of epicardial defibrillation threshold was evaluated in 22 patients, using a patch-patch lead configuration at the time of implantation and generator replacement. The concomitant antiarrhythmic drug treatment consisted of either mexiletine (720 mg/day) or amiodarone (400 mg/day) and was administered to patients in a randomized and parallel manner. During a mean follow-up of 24 +/- 6 months, the defibrillation threshold increased significantly from 14.3 +/- 2.8 to 17.9 +/- 5.3 J (p < 0.05) for the entire patient group. The increase in the chronic defibrillation threshold was due to a marked increase in defibrillation energy needs in the subgroup of patients receiving amiodarone. Whereas no significant change in the defibrillation threshold was documented in the subgroup of patients receiving mexiletine, the mean defibrillation threshold increased from 14.1 +/- 3.0 to 20.9 +/- 5.4 J (p < 0.001) in those receiving amiodarone. In all patients with increased defibrillation thresholds, reevaluation showed a reduction in the defibrillation threshold after discontinuation of antiarrhythmic drug therapy. The only variable associated with an increase in the chronic defibrillation threshold was amiodarone treatment. These findings suggest that the defibrillation threshold should be measured at each generator replacement and in case of a change in antiarrhythmic drug treatment. In particular, if amiodarone treatment is initiated, it is recommended that the defibrillation threshold should be reevaluated to ensure an adequate margin of safety.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1414899     DOI: 10.1016/0002-9149(92)90354-2

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  15 in total

Review 1.  Interactions of antiarrhythmic drugs and implantable devices in controlling ventricular tachycardia and fibrillation.

Authors:  Yadavendra S Rajawat; Darryl Dias; Edward P Gerstenfeld; Sanjay Dixit; Bindi Shah; Andrea M Russo; Francis E Marchlinski
Journal:  Curr Cardiol Rep       Date:  2002-09       Impact factor: 2.931

Review 2.  Combining antiarrhythmic drugs and implantable devices therapy: benefits and outcome.

Authors:  M Santini; C Pandozi; R Ricci
Journal:  J Interv Card Electrophysiol       Date:  2000-01       Impact factor: 1.900

3.  [Influence of amiodarone on defibrillation threshold and perioperative complications in patients with implantable cardioverter-defibrillator with transvenous electrodes and biphasic shocks].

Authors:  W Grimm; V Menz; J Hoffmann; U Timmann; R Moosdorf; B Maisch
Journal:  Herzschrittmacherther Elektrophysiol       Date:  1997-06

Review 4.  Electrical Storm: Current Evidence, Clinical Implications, and Future Perspectives.

Authors:  Christos Kontogiannis; Konstantinos Tampakis; Georgios Georgiopoulos; Stefano Bartoletti; Christos Papageorgiou; Hector Anninos; Alkistis Kapelouzou; Michael Spartalis; Ioannis Paraskevaidis; Sofia Chatzidou
Journal:  Curr Cardiol Rep       Date:  2019-07-27       Impact factor: 2.931

5.  Incidence and clinical predictors of low defibrillation safety margin at time of implantable defibrillator implantation.

Authors:  Zhongwei Cheng; Mintu Turakhia; Ronald Lo; Anurag Gupta; Paul C Zei; Henry H Hsia; Amin Al-Ahmad; Paul J Wang
Journal:  J Interv Card Electrophysiol       Date:  2012-03-06       Impact factor: 1.900

6.  [Is the determination of the defibrillation threshold in patients with an implantable cardioverter-defibrillator still required?].

Authors:  M Licka; L Jahn; K Kelemen; F Voss; K Trappe; R Becker; O Bikou; M Hauck; M Koch; H A Katus; A Bauer
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2011-11-13

Review 7.  Interactions of antiarrhythmic drugs with implantable defibrillator therapy for atrial and ventricular tachyarrhythmias.

Authors:  R B Krol; S Saksena; A Prakash
Journal:  Curr Cardiol Rep       Date:  1999-11       Impact factor: 2.931

8.  Electrical storms in an ICD-recipient with 429 delivered appropriate shocks: therapeutic management with antiarrhythmic drug combination.

Authors:  Athanasios G Manolis; Apostolos G Katsivas; Charis Vassilopoulos; Costas G Tsatiris
Journal:  J Interv Card Electrophysiol       Date:  2002-02       Impact factor: 1.900

9.  [Influence of waveform and configuration of electrodes on the defibrillation threshold of implantable cardioverter-defibrillators].

Authors:  M Block; D Hammel; G Breithardt
Journal:  Herzschrittmacherther Elektrophysiol       Date:  1997-03

Review 10.  Effect of drugs on defibrillation capacity.

Authors:  Anna Legreid Dopp; John M Miller; James E Tisdale
Journal:  Drugs       Date:  2008       Impact factor: 9.546