Literature DB >> 1411963

Quantitation of carbon-11-labeled raclopride in rat striatum using positron emission tomography.

S P Hume1, R Myers, P M Bloomfield, J Opacka-Juffry, J E Cremer, R G Ahier, S K Luthra, D J Brooks, A A Lammertsma.   

Abstract

Using conventional autoradiographic and tissue counting techniques, the experimental quantitation of in vivo kinetics of prospective or established radioligands for PET is animal and labour intensive. The present study tested the feasibility of using PET itself to quantitate the specific binding of [11C]raclopride to rat striatum and to study the effects of experimental manipulation of endogenous dopamine on binding parameters. Carbon-11-labeled raclopride was given i.v. to anaesthetised rats, positioned in a PET camera and dynamic emission scans acquired over 60 min. Time-activity curves were generated for selected regions of interest, representing striatum and cerebellum and the striatal data fitted to a compartmental model, using cerebellum as the input function, thus circumventing the need for individual metabolite-corrected plasma curves. In control rats, the binding potential (BP), defined as the ratio of the rate constants for transfer from "free to bound" and "bound to free" compartments, was of the order of 0.6. This was reduced threefold by predosing with nonradioactive raclopride. Increasing extracellular dopamine levels by predosing with d-amphetamine resulted in a significant decrease in BP whereas reducing extracellular dopamine by predosing with gamma-butyrolactone caused a significant increase. Thus, despite the limitation in spatial resolution of PET, specific binding of raclopride could be assessed from regional time-activity curves from individual rats. The system was sufficiently sensitive that changes in BP could be detected following modulation of endogenous dopamine levels, a finding of potential relevance to the interpretation of clinical PET data.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1411963     DOI: 10.1002/syn.890120106

Source DB:  PubMed          Journal:  Synapse        ISSN: 0887-4476            Impact factor:   2.562


  33 in total

Review 1.  Aspects of PET imaging relevant to the assessment of striatal transplantation in Huntington's disease.

Authors:  L Besret; A L Kendall; S B Dunnett
Journal:  J Anat       Date:  2000-05       Impact factor: 2.610

Review 2.  Small animal imaging facility: new perspectives for the radiologist.

Authors:  R Grassi; C Cavaliere; S Cozzolino; L Mansi; S Cirillo; G Tedeschi; R Franchi; P Russo; S Cornacchia; A Rotondo
Journal:  Radiol Med       Date:  2008-12-11       Impact factor: 3.469

Review 3.  Age-related variability in decision-making: Insights from neurochemistry.

Authors:  Anne S Berry; William J Jagust; Ming Hsu
Journal:  Cogn Affect Behav Neurosci       Date:  2019-06       Impact factor: 3.282

4.  The time course of binding to striatal dopamine D2 receptors by the neuroleptic ziprasidone (CP-88,059-01) determined by positron emission tomography.

Authors:  C J Bench; A A Lammertsma; P M Grasby; R J Dolan; S J Warrington; M Boyce; K P Gunn; L Y Brannick; R S Frackowiak
Journal:  Psychopharmacology (Berl)       Date:  1996-03       Impact factor: 4.530

5.  Noninvasive blood-free full quantification of positron emission tomography radioligand binding.

Authors:  Francesca Zanderigo; R Todd Ogden; Ramin V Parsey
Journal:  J Cereb Blood Flow Metab       Date:  2014-11-05       Impact factor: 6.200

Review 6.  Quantitative Rodent Brain Receptor Imaging.

Authors:  Kristina Herfert; Julia G Mannheim; Laura Kuebler; Sabina Marciano; Mario Amend; Christoph Parl; Hanna Napieczynska; Florian M Maier; Salvador Castaneda Vega; Bernd J Pichler
Journal:  Mol Imaging Biol       Date:  2020-04       Impact factor: 3.488

7.  Reference region approaches in PET: a comparative study on multiple radioligands.

Authors:  Francesca Zanderigo; R Todd Ogden; Ramin V Parsey
Journal:  J Cereb Blood Flow Metab       Date:  2013-02-20       Impact factor: 6.200

8.  Further evaluation of the carbon11-labeled D(2/3) agonist PET radiotracer PHNO: reproducibility in tracer characteristics and characterization of extrastriatal binding.

Authors:  Alice Egerton; Ella Hirani; Rabia Ahmad; David R Turton; Diana Brickute; Lula Rosso; Oliver D Howes; Sajinder K Luthra; Paul M Grasby
Journal:  Synapse       Date:  2010-04       Impact factor: 2.562

9.  Using cerebral white matter for estimation of nondisplaceable binding of 5-HT1A receptors in temporal lobe epilepsy.

Authors:  Giampiero Giovacchini; Shielah Conant; Peter Herscovitch; William H Theodore
Journal:  J Nucl Med       Date:  2009-10-16       Impact factor: 10.057

Review 10.  Imaging the serotonin 1A receptor using [11C]WAY100635 in healthy controls and major depression.

Authors:  Natalie Hesselgrave; Ramin V Parsey
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  2013-02-25       Impact factor: 6.237

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.