Literature DB >> 1409882

Obtaining reliable measurements of knee extensor torque produced during maximal voluntary contractions: an experimental investigation.

J M Kues1, J M Rothstein, R L Lamb.   

Abstract

The purpose of this study was to develop and test a protocol that could be used to obtain reliable measurements of knee extensor torque produced during maximal voluntary contractions. On each of 3 days, 10 subjects performed six consecutive maximal voluntary contractions, in the same randomized order, for each of the following 10 conditions: concentric isokinetic contractions at velocities of 30 degrees, 90 degrees, 120 degrees, and 180 degrees/s; eccentric isokinetic contractions at velocities of 30 degrees, 90 degrees, 120 degrees, and 180 degrees/s; and isometric contractions at 40 and 60 degrees of knee flexion. The peak torques produced were examined to determine on which day and during which contraction subjects produced the greatest torques for each condition. This information was used to develop a practice protocol. Fifteen different subjects were tested following this protocol. Subjects participated in two practice sessions, a test session, and a retest session. Intraclass correlation coefficients (ICCs) were calculated to determine the degree of agreement between torques for the test and retest sessions. The ICCs ranged from .87 to .98. The protocol developed appears to be useful for obtaining reliable measurements of knee extensor torque.

Mesh:

Year:  1992        PMID: 1409882     DOI: 10.1093/ptj/72.7.492

Source DB:  PubMed          Journal:  Phys Ther        ISSN: 0031-9023


  7 in total

1.  Interrater reliability of isokinetic measures of knee flexion and extension.

Authors:  D R Keskula; J S Dowling; V L Davis; P W Finley; D L Dell'omo
Journal:  J Athl Train       Date:  1995-06       Impact factor: 2.860

2.  The Reliability Of Three Isokinetic Knee-extension Angle-specific Torques.

Authors:  B L Arnold; D H Perrin; E V Hellwig
Journal:  J Athl Train       Date:  1993       Impact factor: 2.860

3.  Exercise in patients receiving hematopoietic stem cell transplantation: lessons learned and results from a feasibility study.

Authors:  Eileen Danaher Hacker; Janet L Larson; David Peace
Journal:  Oncol Nurs Forum       Date:  2011-03       Impact factor: 2.172

4.  Reliability of lower extremity strength measures in persons with chronic stroke.

Authors:  Janice J Eng; C Maria Kim; Donna L Macintyre
Journal:  Arch Phys Med Rehabil       Date:  2002-03       Impact factor: 3.966

Review 5.  Isokinetic eccentric exercise.

Authors:  E Kellis; V Baltzopoulos
Journal:  Sports Med       Date:  1995-03       Impact factor: 11.136

6.  Progressive resistance training and cancer testis (PROTRACT) - efficacy of resistance training on muscle function, morphology and inflammatory profile in testicular cancer patients undergoing chemotherapy: design of a randomized controlled trial.

Authors:  Jesper F Christensen; Jesper L Andersen; Lis Adamsen; Birgitte Lindegaard; Abigail L Mackey; Rie H Nielsen; Mikael Rørth; Gedske Daugaard
Journal:  BMC Cancer       Date:  2011-08-01       Impact factor: 4.430

7.  Measurement of force sense reproduction in the knee joint: application of a new dynamometric device.

Authors:  Minoo Khalkhali Zavieh; Bahram Amirshakeri; Asghar Rezasoltani; Ghadam Ali Talebi; Khosro Khademi Kalantari; Vahab Nedaey; Alireza Akbarzadeh Baghban
Journal:  J Phys Ther Sci       Date:  2016-08-31
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.