Literature DB >> 14093

Sampling and storage of blood for pH and blood gas analysis.

S C Haskins.   

Abstract

Techniques used in sampling and storage of a blood sample for pH and gas measurements can have an important effect on the measured values. Observation of these techniques and principles will minimize in vitro alteration of the pH and blood gas values. To consider that a significant change has occurred in a pH or blood gas measurement from previous values, the change must exceed 0.015 for pH, 3 mm Hg for PCO2, 5 mm Hg for PO2, and 2 mEq/L for [HCO-3] or base excess/deficit. In vitro dilution of the blood sample with anticoagulant should be avoided because it will alter the measured PCO2 and base excess/deficit values. Arterial samples should be collected for meaningful pH and blood gas values. Central venous and free-flowing capillary blood can be used for screening procedures in normal patients but are subject to considerable error. A blood sample can be stored for up to 30 minutes at room temperature without significant change in acid-base values but only up to 12 minutes before significant changes occur in PO2. A blood sample can be stored for up to 3.5 hours in an ice-water bath without significant change in pH and for 6 hours without significant change in PCO2 or PO2. Variations of body temperatures from normal will cause a measurable change in pH and blood gas values when the blood is exposed to the normal water bath temperatures of the analyzer.

Entities:  

Mesh:

Substances:

Year:  1977        PMID: 14093

Source DB:  PubMed          Journal:  J Am Vet Med Assoc        ISSN: 0003-1488            Impact factor:   1.936


  4 in total

1.  Changes in CO-oximetry values and pulse oximetry in isoflurane-anesthetized dogs with and without nitrous oxide.

Authors:  Teela Jones; Cindy Feng; Tanya Duke-Novakovski
Journal:  Can J Vet Res       Date:  2020-04       Impact factor: 1.310

2.  Central venous blood gas and acid-base status in conscious dogs and cats.

Authors:  Jun Tamura; Takaharu Itami; Tomohito Ishizuka; Sho Fukui; Kenjirou Miyoshi; Tadashi Sano; Kazuto Yamashita
Journal:  J Vet Med Sci       Date:  2015-03-05       Impact factor: 1.267

3.  Influence of different storage times and temperatures on blood gas and acid-base balance in ovine venous blood.

Authors:  H A Hussein; A A Aamer
Journal:  Open Vet J       Date:  2013-01-03

4.  Stability of hematological parameters of canine blood samples stored with citrate phosphate dextrose adenine-1 anticoagulated plastic vacutainers.

Authors:  Okereke Henry Nnamdi; Udegbunam Rita Ijeoma; Nnaji Theophilus Okaforx
Journal:  Vet World       Date:  2019-03-25
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.