Literature DB >> 1409077

Comparative quantitative study of Ki-67 antibody staining in 78 B and T cell malignant lymphoma (ML) using two image analyser systems.

S Caulet1, C Lesty, M Raphael, D Schoevaert, P Brousset, J L Binet, J Diebold, G Delsol.   

Abstract

Total Ki-67 stained area percentage was studied in 32 B and 46 T malignant lymphomas (ML) using two different image analyser systems (TAS, Leitz; SAMBA TM 2005, TITN) respectively. The total Ki-67 area percentage was highly correlated to the number of Ki-67 positive cellular profiles (B-ML, r = 0.93; T-ML, r = 0.88), indicating that area percentage is a reliable alternative method to the manual cell counting. Image analysis allows quicker measurements, appropriate to large and strictly lymphomatous regions. The cell image processor (SAMBA TM 2005, TITN) linked to a color video camera was more suitable for immunohistochemical sections and allowed more automated and faster measurements than the texture analyser (TAS, Leitz) linked with a black and white camera. Alkaline phosphatase technique with fast red as chromogen was more suitable for the detection of Ki-67 stained area by thresholding than peroxidase technique with aminoethylcarbazol or with diaminobenzidine as chromogens. Significant differences were found between low and high grade in B and T ML according to the Kiel classification (mean values +/- SD of 7.7 +/- 3.8% and 16.6 +/- 6.2% in B-ML and of 10.2 +/- 7.9% and 25.6 +/- 16.3% in T-ML respectively). In follicular B-ML, considering follicular areas only, values were comparable to high grade ML; angioimmunoblastic-lymphadenopathy-like (AILD-type) T-ML belonging to low grade ML showed similar values to pleomorphic T-ML with medium and/or large cells belonging to high grade ML.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1409077     DOI: 10.1016/S0344-0338(11)80043-9

Source DB:  PubMed          Journal:  Pathol Res Pract        ISSN: 0344-0338            Impact factor:   3.250


  2 in total

Review 1.  Image analysis tools for evaluation of microscopic views of immunohistochemically stained specimen in medical research-a review.

Authors:  Keerthana Prasad; Gopalakrishna K Prabhu
Journal:  J Med Syst       Date:  2011-05-17       Impact factor: 4.460

2.  Computer-aided image analysis applied to immunogold-silver staining: evaluation of proliferating cell nuclear antigen (PCNA)-reactive sites in paraffin sections.

Authors:  Y Tajima; K Kato; N Utsumi; K Hosoi
Journal:  Histochemistry       Date:  1994-09
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.