Literature DB >> 1406331

Validation of the AI/RHEUM knowledge base with data from consecutive rheumatological outpatients.

H J Bernelot Moens1.   

Abstract

The diagnostic accuracy of AI/RHEUM, an experimental expert system for support in the diagnosis of rheumatic diseases, was assessed using a collection of data in a cohort of 1,570 consecutive outpatients of a Dutch rheumatological clinic. Computer diagnoses based on these data and diagnostic predictions made by rheumatologists were compared with reference diagnoses that had been obtained by consensus of rheumatologists after 6-12 months follow-up. Performance of the tested version of the AI/RHEUM knowledge base is presented by various methods. Sensitivity varied between 29% and 100% for different rheumatological diseases. Average sensitivity and specificity for all 26 diagnoses present in the knowledge base were 67% and 98%, respectively. Performance according to the level of confidence indicated that 78% of the "definite", 65% of the "probable", and 33% of the "possible" conclusions made by AI/RHEUM were in agreement with the reference diagnoses. These results approximated the predictions made by rheumatologists after a single, initial examination. The system was less accurate than it had appeared in previous evaluation studies with complex clinical cases. The AI/RHEUM knowledge base needed refining to diagnose early rheumatic complaints. This study further illustrates the need for objective and informative parameters for expressing accuracy of diagnostic support systems.

Entities:  

Mesh:

Year:  1992        PMID: 1406331

Source DB:  PubMed          Journal:  Methods Inf Med        ISSN: 0026-1270            Impact factor:   2.176


  4 in total

1.  New approaches to measuring the performance of programs that generate differential diagnoses using ROC curves and other metrics.

Authors:  H S Fraser; S Naimi; W J Long
Journal:  Proc AMIA Symp       Date:  2000

2.  Reference standards, judges, and comparison subjects: roles for experts in evaluating system performance.

Authors:  George Hripcsak; Adam Wilcox
Journal:  J Am Med Inform Assoc       Date:  2002 Jan-Feb       Impact factor: 4.497

3.  Evaluation of a cardiac diagnostic program in a typical clinical setting.

Authors:  Hamish S F Fraser; William J Long; Shapur Naimi
Journal:  J Am Med Inform Assoc       Date:  2003-03-28       Impact factor: 4.497

Review 4.  Computer-based diagnostic expert systems in rheumatology: where do we stand in 2014?

Authors:  Hannes Alder; Beat A Michel; Christian Marx; Giorgio Tamborrini; Thomas Langenegger; Pius Bruehlmann; Johann Steurer; Lukas M Wildi
Journal:  Int J Rheumatol       Date:  2014-07-08
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.