The dimensional accuracy of rectangular acrylic resin specimens cured by three denture base processing methods.

S Salim1, S Sadamori, T Hamada.   

Abstract

The dimensional accuracy of rectangular acrylic resin specimens was examined when they were processed by three methods: a conventional method, the SR-Ivocap system, and a microwave curing method. The dimensional accuracy was evaluated by the change of the distance vector V, which is calculated by means of measurements of the distances between fixed points on specimens. The specimen cured by the SR-Ivocap system exhibited less dimensional change (p less than 0.05) than those cured by the conventional and the microwave curing methods. The SR-Ivocap system might produce a more accurate denture base than the conventional and the microwave curing methods.

Mesh:

Substances:

Year:  1992        PMID: 1403883     DOI: 10.1016/0022-3913(92)90606-b

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  7 in total

1.  A Comparative Evaluation of the Linear Dimensional Changes of Two Different Commercially Available Heat Cure Acrylic Resins during Three Different Cooling Regimens.

Authors:  Abhishek Savirmath; Vandita Mishra
Journal:  J Clin Diagn Res       Date:  2016-11-01

2.  Effect of different palatal vault shapes on the dimensional stability of glass fiber-reinforced heat-polymerized acrylic resin denture base material.

Authors:  Mehmet Dalkiz; Demet Arslan; Ali Riza Tuncdemir; M Selim Bilgin; Halil Aykul
Journal:  Eur J Dent       Date:  2012-01

3.  Effect of surface treatments on shear bond strength of denture teeth to denture base resins.

Authors:  Farideh Bahrani; Amir Ali Reza Khaledi
Journal:  Dent Res J (Isfahan)       Date:  2014-01

4.  A comparison of shear bond strength of ceramic and resin denture teeth on different acrylic resin bases.

Authors:  Massimo Corsalini; Daniela Di Venere; Francesco Pettini; Gianluca Stefanachi; Santo Catapano; Antonio Boccaccio; Luciano Lamberti; Carmine Pappalettere; Stefano Carossa
Journal:  Open Dent J       Date:  2014-12-29

5.  Dimensional changes of acrylic resin denture bases: conventional versus injection-molding technique.

Authors:  Jafar Gharechahi; Nafiseh Asadzadeh; Foad Shahabian; Maryam Gharechahi
Journal:  J Dent (Tehran)       Date:  2014-07-31

6.  Flexural strength of acrylic resin denture bases processed by two different methods.

Authors:  Jafar Gharechahi; Nafiseh Asadzadeh; Foad Shahabian; Maryam Gharechahi
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2014-09-17

7.  Evaluation of Three Different Processing Techniques in the Fabrication of Complete Dentures.

Authors:  Vamsi Krishna Chintalacheruvu; Rajasekaran Uttukuli Balraj; Lavanya Sireesha Putchala; Sreelekha Pachalla
Journal:  J Int Soc Prev Community Dent       Date:  2017-06-20
  7 in total