Literature DB >> 1402269

The Herbert bone screw: a ten year perspective.

T J Herbert1, W E Fisher, A W Leicester.   

Abstract

It is now over ten years since the Herbert bone screw was first released in Australia. In 1984, Herbert and Fisher first published their experience with the use of this new bone screw in the management of scaphoid fractures. Since that time, there has been a growing interest in the technique and over 60 articles have appeared in the English literature. The purpose of this paper is to review and comment on the relevant publications as they relate to the biomechanical properties of the screw, to its use in the management of scaphoid fractures and to other applications in surgery of the hand.

Entities:  

Mesh:

Year:  1992        PMID: 1402269     DOI: 10.1016/s0266-7681(05)80265-7

Source DB:  PubMed          Journal:  J Hand Surg Br        ISSN: 0266-7681


  8 in total

1.  Insertion profiles of 4 headless compression screws.

Authors:  Adam Hart; Edward J Harvey; Louis-Philippe Lefebvre; Francois Barthelat; Reza Rabiei; Paul A Martineau
Journal:  J Hand Surg Am       Date:  2013-06-25       Impact factor: 2.230

2.  [Navigation for placement of scaphoid screws : a new indication for intraoperative 3D navigation-a cadaver study].

Authors:  D Kendoff; M Citak; R Gaulke; M J Gardner; J Geerling; C Krettek; T Hüfner
Journal:  Unfallchirurg       Date:  2007-09       Impact factor: 1.000

3.  Fixation of scaphoid delayed union and non-union with absorbable polyglycolide pin or Herbert screw. Consolidation and functional results.

Authors:  K Pelto-Vasenius; E Hirvensalo; O Böstman; P Rokkanen
Journal:  Arch Orthop Trauma Surg       Date:  1995       Impact factor: 3.067

Review 4.  The Scaphoid Staple: A Systematic Review.

Authors:  John Dunn; Nicholas Kusnezov; Austin Fares; Justin Mitchell; Miguel Pirela-Cruz
Journal:  Hand (N Y)       Date:  2016-07-07

Review 5.  Current concepts for the treatment of acute scaphoid fractures.

Authors:  A Arsalan-Werner; M Sauerbier; I M Mehling
Journal:  Eur J Trauma Emerg Surg       Date:  2015-11-25       Impact factor: 3.693

6.  Scaphoid Fracture Repair Does Not Significantly Diminish Short-Term Participation in the National Football League.

Authors:  Derrick M Knapik; Leigh-Anne Tu; Joseph Sheehan; Michael J Salata; James E Voos; Kevin J Malone
Journal:  HSS J       Date:  2018-11-05

7.  Evaluation of the mechanical properties and clinical application of nickel-titanium shape memory alloy scaphoid arc nail.

Authors:  Muguo Song; Yongyue Su; Chuan Li; Yongqing Xu
Journal:  Eng Life Sci       Date:  2021-03-09       Impact factor: 2.678

8.  Biodegradable magnesium-based screw clinically equivalent to titanium screw in hallux valgus surgery: short term results of the first prospective, randomized, controlled clinical pilot study.

Authors:  Henning Windhagen; Kerstin Radtke; Andreas Weizbauer; Julia Diekmann; Yvonne Noll; Ulrike Kreimeyer; Robert Schavan; Christina Stukenborg-Colsman; Hazibullah Waizy
Journal:  Biomed Eng Online       Date:  2013-07-03       Impact factor: 2.819

  8 in total