Literature DB >> 1395377

Transjugular liver biopsy: a review of 200 biopsies.

P Corr1, S J Beningfield, N Davey.   

Abstract

Transjugular liver biopsy was performed in 200 patients for whom percutaneous biopsy was contraindicated because of coagulation disorders (36%), ascites (32%) or for the work-up of portal hypertension (32%). An adequate biopsy allowing a histological diagnosis was obtained in 155 patients (77%). The biopsy was inadequate in 13 patients (6.5%). In 32 patients (16%) the biopsy failed. Complications occurred in 18 patients (9%). Twelve (6%) patients developed liver capsule perforations which were immediately embolized without complication. Inadvertent carotid artery puncture and supraventricular tachycardias occurred in three patients each. Transjugular liver biopsy is a valuable technique which provides information which would otherwise be unavailable in those patients for whom percutaneous biopsy is considered unsafe.

Entities:  

Mesh:

Year:  1992        PMID: 1395377     DOI: 10.1016/s0009-9260(05)80004-2

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  5 in total

Review 1.  An appraisal of the histopathological assessment of liver fibrosis.

Authors:  R A Standish; E Cholongitas; A Dhillon; A K Burroughs; A P Dhillon
Journal:  Gut       Date:  2006-04       Impact factor: 23.059

2.  Transfemoral liver biopsy by forceps: a review of 104 consecutive procedures.

Authors:  J P Teare; A F Watkinson; S R Erb; J R Mayo; D G Connell; I H Weir; D A Owen; R Wolber; D C Morris
Journal:  Cardiovasc Intervent Radiol       Date:  1994 Sep-Oct       Impact factor: 2.740

Review 3.  Transjugular liver biopsy: a review of 77 biopsies using a spring-propelled cutting needle (biopsy gun).

Authors:  E Gorriz; R Reyes; M B Lobrano; J M Pulido-Duque; J L San Roman; E Lonjedo; H Ferral; M Maynar
Journal:  Cardiovasc Intervent Radiol       Date:  1996 Nov-Dec       Impact factor: 2.740

4.  Two cases of major hemorrhage secondary to transjugular liver biopsy.

Authors:  George E Lynskey; Elliot B Levy; Filip Banovac
Journal:  Semin Intervent Radiol       Date:  2007-09       Impact factor: 1.513

5.  Comparison of a new aspiration needle device and the Quick-Core biopsy needle for transjugular liver biopsy.

Authors:  Toru Ishikawa; Hiroteru Kamimura; Atsunori Tsuchiya; Tadayuki Togashi; Kouji Watanabe; Kei Seki; Hironobu Ohta; Toshiaki Yoshida; Noriko Ishihara; Tomoteru Kamimura
Journal:  World J Gastroenterol       Date:  2006-10-21       Impact factor: 5.742

  5 in total