Literature DB >> 1395302

Force- and moment-generating capacity of lower-extremity muscles before and after tendon lengthening.

S L Delp1, F E Zajac.   

Abstract

A computer model of the human lower extremity was developed to study how surgical lengthening of tendon affects the force- and moment-generating capacity of the muscles. This model computes the maximum isometric force and the resulting joint moments that each muscle-tendon complex can develop at any body position. Tendon lengthenings were simulated by increasing the tendon length of each muscle-tendon complex and computing the change in the maximum isometric muscle force and joint moments at a specific body position. These simulations showed that the forces and moments developed by the ankle plantarflexors are extremely sensitive to changes in tendon length. For example, at a body position corresponding to the midstance phase of gait, the maximum isometric moment generated by soleus decreased 30% with a 1-cm increase in tendon length, and 85% with a 2-cm increase in tendon length. In contrast, 1- and 2-cm increases in iliopsoas tendon length decreased its hip flexion moment by only 4% and 9%, respectively. This article quantifies the sensitivity of muscle force and joint moments to changes in tendon length for the most commonly lengthened lower-extremity tendons. These results indicate how much each of these tendons should be lengthened to achieve an incremental decrease in muscle force or joint moment.

Entities:  

Mesh:

Year:  1992        PMID: 1395302

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  22 in total

1.  Modelling the masticatory biomechanics of a pig.

Authors:  G E J Langenbach; F Zhang; S W Herring; A G Hannam
Journal:  J Anat       Date:  2002-11       Impact factor: 2.610

2.  [The surgical management of spastic foot deformities].

Authors:  L Döderlein
Journal:  Orthopade       Date:  2004-10       Impact factor: 1.087

Review 3.  [Bilateral spastic cerebral palsy with ambulatory ability (diplegia): pathophysiology, state of the art of conservative and surgical treatment and rehabilitation].

Authors:  B Westhoff; D Bittersohl; R Krauspe
Journal:  Orthopade       Date:  2014-07       Impact factor: 1.087

Review 4.  Intra- and Inter-Muscular Variations in Hamstring Architecture and Mechanics and Their Implications for Injury: A Narrative Review.

Authors:  Eleftherios Kellis
Journal:  Sports Med       Date:  2018-10       Impact factor: 11.136

5.  Variation of hamstrings lengths and velocities with walking speed.

Authors:  Kiran J Agarwal-Harding; Michael H Schwartz; Scott L Delp
Journal:  J Biomech       Date:  2010-04-08       Impact factor: 2.712

Review 6.  [Spastic equinus foot].

Authors:  B Westhoff; K Weimann-Stahlschmidt; R Krauspe
Journal:  Orthopade       Date:  2011-07       Impact factor: 1.087

7.  Sensitivity of estimated muscle force in forward simulation of normal walking.

Authors:  Ming Xiao; Jill Higginson
Journal:  J Appl Biomech       Date:  2010-05       Impact factor: 1.833

Review 8.  Use it or lose it: multiscale skeletal muscle adaptation to mechanical stimuli.

Authors:  Katrina M Wisdom; Scott L Delp; Ellen Kuhl
Journal:  Biomech Model Mechanobiol       Date:  2014-09-09

9.  [Irritation of the iliopsoas tendon after total hip arthroplasty].

Authors:  M H Hessmann; L Hübschle; M Tannast; K A Siebenrock; R Ganz
Journal:  Orthopade       Date:  2007-08       Impact factor: 1.087

10.  Treatment of Hip Flexion Contractures with Psoas Recession Through the Middle Window of the Ilioinguinal Approach.

Authors:  Daniel J Gittings; Jonathan R Dattilo; George Fryhofer; Derek J Donegan; Keith Baldwin
Journal:  JBJS Essent Surg Tech       Date:  2017-08-23
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.