Literature DB >> 13907010

Rupture of abdominal aortic aneurysm: control of hemorrhage by intraluminal balloon tamponade.

F G HESSE, H D KLETSCHKA.   

Abstract

Entities:  

Keywords:  AORTIC ANEURYSM/surgery

Mesh:

Year:  1962        PMID: 13907010      PMCID: PMC1466047          DOI: 10.1097/00000658-196200000-00025

Source DB:  PubMed          Journal:  Ann Surg        ISSN: 0003-4932            Impact factor:   12.969


× No keyword cloud information.
  5 in total

1.  A review of seven years' experience with excision and graft replacement in 150 ruputured and unruptured aneurysms of the abdominal aorta.

Authors:  P F GRYSKA; C G WHEELER; R R LINTON
Journal:  N Engl J Med       Date:  1961-03-30       Impact factor: 91.245

2.  Ruptured abdominal aortic aneurysm.

Authors:  J A ELLIOT; A D McKENZIE; W B CHUNG
Journal:  Surgery       Date:  1959-09       Impact factor: 3.982

3.  Ruptured abdominal aneurysm; transthoracic control.

Authors:  K A MERENDINO
Journal:  Surg Gynecol Obstet       Date:  1956-11

4.  Resection of ruptured aneurysms of the abdominal aorta.

Authors:  H JAVID; W S DYE; W J GROVE; O C JULIAN
Journal:  Ann Surg       Date:  1955-10       Impact factor: 12.969

5.  Intraluminal aortic occlusion as a possible mechanism for controlling massive intra-abdominal hemorrhage.

Authors:  W S EDWARDS; P P SALTER; V A CARNAGGIO
Journal:  Surg Forum       Date:  1953-10
  5 in total
  5 in total

1.  Aortic occlusion balloon catheter technique is useful for uncontrollable massive intraabdominal bleeding after hepato-pancreato-biliary surgery.

Authors:  Fumihiko Miura; Tadahiro Takada; Takenori Ochiai; Takehide Asano; Takashi Kenmochi; Hodaka Amano; Masahiro Yoshida
Journal:  J Gastrointest Surg       Date:  2006-04       Impact factor: 3.452

2.  Endovascular grafts and other image-guided catheter-based adjuncts to improve the treatment of ruptured aortoiliac aneurysms.

Authors:  T Ohki; F J Veith
Journal:  Ann Surg       Date:  2000-10       Impact factor: 12.969

3.  Intra-arterial occlusion in vascular surgery.

Authors:  J J McCaughan; J M Young
Journal:  Ann Surg       Date:  1970-05       Impact factor: 12.969

4.  Control of aortic haemorrhage by balloon catheter.

Authors:  E R Howard; A E Young
Journal:  Br Med J       Date:  1971-07-17

Review 5.  A systematic review and meta-analysis of the use of resuscitative endovascular balloon occlusion of the aorta in the management of major exsanguination.

Authors:  B L S Borger van der Burg; Thijs T C F van Dongen; J J Morrison; P P A Hedeman Joosten; J J DuBose; T M Hörer; R Hoencamp
Journal:  Eur J Trauma Emerg Surg       Date:  2018-05-21       Impact factor: 3.693

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.