Literature DB >> 1390574

Shear bond strength of ceramic brackets with chemical or mechanical retention.

C M Forsberg1, C Hagberg.   

Abstract

The study was undertaken to measure and compare the shear bond strengths of a ceramic bracket with chemical retention, a ceramic bracket with a new type of textured base providing mechanical retention, and a metal bracket with foil-mesh base. The tests were performed on 51 extracted human premolars which were randomly divided into three equally large groups (n = 17)--one group for each type of bracket. After debonding, the site of failure was noted and the enamel surface inspected with scanning electron microscopy. The ceramic bracket with chemical retention exhibited significantly higher bond strength than the corresponding bracket with textured base. In comparison with the metal bracket significantly higher bond strengths were recorded for both types of ceramic brackets. The ceramic bracket with mechanical retention and the metal bracket were comparable as regards the site of bond failure. In some cases the chemical bond provided very high values of bond strength. Enamel failure were recorded in three teeth which had been bonded with this type of ceramic bracket.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1390574     DOI: 10.1179/bjo.19.3.183

Source DB:  PubMed          Journal:  Br J Orthod        ISSN: 0301-228X


  6 in total

1.  Reconditioning of ceramic orthodontic brackets with an Er,Cr:YSGG laser.

Authors:  Farzaneh Ahrari; Reza Fekrazad; Katayoun A M Kalhori; Mahshid Ramtin
Journal:  Lasers Med Sci       Date:  2012-05-15       Impact factor: 3.161

2.  Shear bond strength of an experimental composite bracket.

Authors:  Zhe-chen Zhang; Russell Giordano; Gang Shen; L Lee Chou; Yu-fen Qian
Journal:  J Orofac Orthop       Date:  2013-06-28       Impact factor: 1.938

3.  Shear bond strength and enamel fracture behavior of ceramic brackets Fascination® and Fascination®2.

Authors:  Robert Gittner; Ralf Müller-Hartwich; Sylvia Engel; Paul-Georg Jost-Brinkmann
Journal:  J Orofac Orthop       Date:  2012-01-15       Impact factor: 1.938

4.  Effect of Er:YAG Laser and Sandblasting in Recycling of Ceramic Brackets.

Authors:  Soghra Yassaei; Hossein Aghili; Azadeh Hosseinzadeh Firouzabadi; Hamidreza Meshkani
Journal:  J Lasers Med Sci       Date:  2017-01-08

5.  Does ultra-pulse CO(2) laser reduce the risk of enamel damage during debonding of ceramic brackets?

Authors:  Farzaneh Ahrari; Farzin Heravi; Reza Fekrazad; Fahimeh Farzanegan; Samaneh Nakhaei
Journal:  Lasers Med Sci       Date:  2011-06-11       Impact factor: 3.161

6.  Effect of the different debonding strength of metal and ceramic brackets on the degree of enamel microcrack healing.

Authors:  Piyaphong Nimplod; Ratchawan Tansalarak; Tanapon Sornsuwan
Journal:  Dental Press J Orthod       Date:  2021-06-25
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.