Literature DB >> 1389286

Heart valve bioprosthesis durability: a challenge to the new generation of porcine valves.

M Valente1, M Minarini, A F Maizza, U Bortolotti, G Thiene.   

Abstract

Long-term experience with first generation porcine valve xenografts enabled identification of the major limitations to their durability: (1) prosthetic-ventricular mismatch due to the high profile of the stent in patients with mitral stenosis and a small left ventricle; (2) high-pressure fixation with loss of natural collagen crimping in the fibrosa, and wash-out of proteoglycans in the spongiosa; (3) xenograft tissue autolysis, due to the long interval between animal slaughter and aortic valve removal fixation; (4) muscle shelf in the right coronary cusp, which created a gradient and could undergo accelerated calcification and/or spontaneous perforation with time; (5) a flexible polypropylene stent, which could creep or even fracture with consequent inward bending of the stent; (6) progressive time-related dystrophic calcification; (7) host fibrous tissue ingrowth. An awareness of these limitations stimulated technical modifications, which frequently brought about distinct improvements: (1) the reduction of the stent profile eliminated the problem of mismatch, but resulted in a higher tendency towards cusp prolapse and earlier commissural tearing; (2) natural collagen waviness, proteoglycans and cusp extensibility were preserved by employing low or even zero pressure during the fixation process; (3) earlier valve fixation enabled preservation of cell integrity; (4) a new orifice for small valves was designed by replacing the right muscular cusp, thus achieving less gradient and avoiding muscle-shelf-related complications; (5) polypropylene was replaced by Delrin as stent material; (6) calcium-retarding agents like T6 and toluidine blue were applied during commercial processing and storage in order to mitigate tissue mineralization.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1992        PMID: 1389286

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  2 in total

1.  Design and Testing of a Pulsatile Conditioning System for Dynamic Endothelialization of Polyphenol-Stabilized Tissue Engineered Heart Valves.

Authors:  Leslie Neil Sierad; Agneta Simionescu; Christopher Albers; Joseph Chen; Jordan Maivelett; Mary Elizabeth Tedder; Jun Liao; Dan T Simionescu
Journal:  Cardiovasc Eng Technol       Date:  2010-06       Impact factor: 2.495

2.  Screening biomaterials with a new in vitro method for potential calcification: porcine aortic valves and bovine pericardium.

Authors:  D Mavrilas; J Kapolos; P G Koutsoukos; D Dougenis
Journal:  J Mater Sci Mater Med       Date:  2004-06       Impact factor: 3.896

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.