Literature DB >> 13862405

A clinical evaluation of the Rygg-Kyvsgaard III and the mark II pump oxygenators.

E ARNFRED, I H RYGG, T FREDERIKSEN, H C ENGELL, T POULSEN, J ROSEN.   

Abstract

Keywords:  HEART, MECHANICAL

Mesh:

Year:  1961        PMID: 13862405      PMCID: PMC1018644          DOI: 10.1136/thx.16.4.309

Source DB:  PubMed          Journal:  Thorax        ISSN: 0040-6376            Impact factor:   9.139


× No keyword cloud information.
  11 in total

1.  A Micro method for determination of pH, carbon dioxide tension, base excess and standard bicarbonate in capillary blood.

Authors:  O S ANDERSEN; K ENGEL; K JORGENSEN; P ASTRUP
Journal:  Scand J Clin Lab Invest       Date:  1960       Impact factor: 1.713

2.  Clinical experience with Rygg-Kyvsgaard's heart-lung machine.

Authors:  F THERKELSEN; T POULSEN; J ROSEN; I RYGG
Journal:  Acta Chir Scand       Date:  1961-10

3.  Clinical comparison between a stationary-screen oxygenator and a bubble-oxygenator in total body perfusion.

Authors:  H C ENGELL; I RYGG; E ARNFRED; T FREDERIKSEN; T POULSEN
Journal:  Acta Chir Scand       Date:  1961-10

4.  An experimental and clinical comparison of the bubble dispersion and stationary screen pump oxygenators.

Authors:  J V MALONEY; W P LONGMIRE; K J SCHMUTZER; S A MARABLE; E RASCHKE; Y WATANABE; E L LOBPREIS; J E ARZOUMAN
Journal:  Surg Gynecol Obstet       Date:  1958-11

5.  Oxygen consumption during cardiopulmonary bypass.

Authors:  A STARR
Journal:  J Thorac Cardiovasc Surg       Date:  1959-07       Impact factor: 5.209

6.  Further development of the heart-lung machine with the Rygg-Kyvsgaard plastic bag oxygenator.

Authors:  I H RYGG; E KYVSGAARD
Journal:  Minerva Chir       Date:  1958-12-15       Impact factor: 1.000

7.  The clinical use of a screen oxygenator (Mark III) in closure of atrial septum primum defects.

Authors:  E HUSFELDT; H C ENGELL; O JUHL; J ROSEN; E SANDOE; E ARNFRED
Journal:  Acta Chir Scand Suppl       Date:  1959

8.  Experimental open heart surgery using a heart-lung machine with a simple disposable oxygenator.

Authors:  P A GAMMELGAARD; E HUSFELDT; F THERKELSEN
Journal:  Acta Chir Scand       Date:  1957-05-25

9.  [Extracorporeal circulation in intracardiac surgery; a comparison between two heart-lung machines].

Authors:  F GERBODE; J J OSBORN; D G MELROSE; H A PERKINS; A NORMAN; D M BAER
Journal:  Lancet       Date:  1958-08-09       Impact factor: 79.321

10.  Liver blood flow and general anaesthesia.

Authors:  R SHACKMAN; I G GRABER; D G MELROSE
Journal:  Clin Sci       Date:  1953       Impact factor: 6.124

View more
  3 in total

1.  GAS EXCHANGE IN THE RYGG-KYVSGAARD BUBBLE OXYGENATOR.

Authors:  I H RYGG; T FREDERIKSEN; M JORGENSEN
Journal:  Thorax       Date:  1963-09       Impact factor: 9.139

2.  Prolonged extracorporeal circulation.

Authors:  T FREDERIKSEN; J ROSEN; I H RYGG; E CHRISTENSEN; F THERKELSEN
Journal:  Thorax       Date:  1963-06       Impact factor: 9.139

3.  The fate of preserved homograft pericardium and autogenous pericardium within the heart.

Authors:  C P Clarke; B G Barratt-Boyes; F H Sims
Journal:  Thorax       Date:  1968-03       Impact factor: 9.139

  3 in total