Literature DB >> 1375714

Role of magnetic resonance imaging in the evaluation of the hydroxyapatite orbital implant.

P De Potter1, C L Shields, J A Shields, A E Flanders, V M Rao.   

Abstract

The role of magnetic resonance imaging (MRI) in the assessment of fibrovascular ingrowth in the integrated hydroxyapatite orbital implant is evaluated. Fifteen patients who underwent enucleation and placement of a hydroxyapatite orbital implant were evaluated for degree of implant vascularity with gadolinium-DPTA-enhanced MRI with surface coil before drilling the implant. On T1-weighted images, the hydroxyapatite sphere appeared with intermediate signal. After gadolinium-DPTA administration, all patients showed an enhancement in the implant consistent with the presence of fibrovascular ingrowth. The enhancement was most notable in the peripheral portions of the sphere and was seen as early as 5 months after implantation. Comparison of gadolinium-DPTA-enhanced MRI with contrast-enhanced computed tomography, ultrasonography, and color Doppler imaging suggests that these latter techniques are not as helpful in the detection of the fibrovascular tissue in the orbital implant. Bone scan, a technique used by many surgeons, demonstrates fibrovascular ingrowth, but it is limited by its one-dimensional low-resolution image. Because of its three-dimensional capability and its highest resolution, contrast-enhanced MRI with surface coil appears to be the best imaging method for evaluating the hydroxyapatite orbital implant and its fibrovascular ingrowth.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1375714     DOI: 10.1016/s0161-6420(92)31918-9

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  6 in total

1.  Correlation of histological findings with gadolinium enhanced MRI scans during healing of a PHEMA orbital implant in rabbits.

Authors:  C R Hicks; I T Morris; S Vijayasekaran; M J Fallon; J McAllister; A B Clayton; T V Chirila; G J Crawford; I J Constable
Journal:  Br J Ophthalmol       Date:  1999-05       Impact factor: 4.638

2.  Lack of complications of the hydroxyapatite orbital implant in 250 consecutive cases.

Authors:  C L Shields; J A Shields; P De Potter; A D Singh
Journal:  Trans Am Ophthalmol Soc       Date:  1993

3.  Problems with the hydroxyapatite orbital implant: experience with 250 consecutive cases.

Authors:  C L Shields; J A Shields; P De Potter; A D Singh
Journal:  Br J Ophthalmol       Date:  1994-09       Impact factor: 4.638

4.  MRI of orbital hydroxyapatite implants.

Authors:  A E Flanders; P De Potter; V M Rao; B M Tom; C L Shields; J A Shields
Journal:  Neuroradiology       Date:  1996-04       Impact factor: 2.804

Review 5.  Nanotechnology-based strategies for treatment of ocular disease.

Authors:  Yuhua Weng; Juan Liu; Shubin Jin; Weisheng Guo; Xingjie Liang; Zhongbo Hu
Journal:  Acta Pharm Sin B       Date:  2016-11-18       Impact factor: 11.413

6.  Magnetic Resonance Imaging of Postoperative Fracture Healing Process without Metal Artifact: A Preliminary Report of a Novel Animal Model.

Authors:  Zhe Jin; Yuheng Guan; Guibo Yu; Yu Sun
Journal:  Biomed Res Int       Date:  2016-03-31       Impact factor: 3.411

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.