Literature DB >> 1368367

Biosensors for process monitoring.

T Scheper1.   

Abstract

A short review about the biosensor research activities for bioprocess monitoring in the F.R.G. after its reunification is given. The principles of biosensor applications are presented. In situ sensors and sensors based on the principles of flow injection analysis are studied. Some applications of a four-channel enzyme thermistor, bio-field effect transistors, and immunoanalysis systems for real process monitoring are presented.

Mesh:

Year:  1992        PMID: 1368367     DOI: 10.1007/bf01569620

Source DB:  PubMed          Journal:  J Ind Microbiol        ISSN: 0169-4146


  8 in total

Review 1.  Immuno- and flow cytometric analytical methods for biotechnological research and process monitoring.

Authors:  A Degelau; R Freitag; F Linz; C Middendorf; T Scheper; T Bley; S Müller; P Stoll; K F Reardon
Journal:  J Biotechnol       Date:  1992-08       Impact factor: 3.307

2.  On-line determination of glucose in biotechnological processes: comparison between FIA and an in situ enzyme electrode.

Authors:  C Filippini; B Sonnleitner; A Fiechter; J Bradley; R Schmid
Journal:  J Biotechnol       Date:  1991-04       Impact factor: 3.307

Review 3.  Flow injection analysis (FIA) based on enzymes or antibodies--applications in the life sciences.

Authors:  R D Schmid; W Künnecke
Journal:  J Biotechnol       Date:  1990-04       Impact factor: 3.307

4.  Development of a turbidimetric immunoassay for on-line monitoring of proteins in cultivation processes.

Authors:  R Freitag; T Scheper; K Schügerl
Journal:  Enzyme Microb Technol       Date:  1991-12       Impact factor: 3.493

5.  On-line determination of glucose concentration throughout animal cell cultures based on chemiluminescent detection of hydrogen peroxide coupled with flow-injection analysis.

Authors:  Y L Huang; S Y Li; B A Dremel; U Bilitewski; R D Schmid
Journal:  J Biotechnol       Date:  1991-04       Impact factor: 3.307

6.  On-line determination of glucose and lactate concentrations in animal cell culture based on fibre optic detection of oxygen in flow-injection analysis.

Authors:  B A Dremel; S Y Li; R D Schmid
Journal:  Biosens Bioelectron       Date:  1992       Impact factor: 10.618

7.  On-line monitoring of monoclonal antibody formation in high density perfusion culture using FIA.

Authors:  C Fenge; E Fraune; R Freitag; T Scheper; K Schügerl
Journal:  Cytotechnology       Date:  1991-05       Impact factor: 2.058

8.  Monitoring and control of biotechnological production processes by Bio-FET-FIA-sensors.

Authors:  U Brand; L Brandes; V Koch; T Kullik; B Reinhardt; F Rüther; T Scheper; K Schügerl; S Wang; X Wu
Journal:  Appl Microbiol Biotechnol       Date:  1991-11       Impact factor: 4.813

  8 in total
  1 in total

1.  Optical biosensor for environmental on-line monitoring of naphthalene and salicylate bioavailability with an immobilized bioluminescent catabolic reporter bacterium.

Authors:  A Heitzer; K Malachowsky; J E Thonnard; P R Bienkowski; D C White; G S Sayler
Journal:  Appl Environ Microbiol       Date:  1994-05       Impact factor: 4.792

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.