Literature DB >> 13610933

A comparison of scanning and two-wavelength microspectrophotometry.

M L MENDELSOHN, B M RICHARDS.   

Abstract

Because of the absence of suitable standards, microspectrophotometry suffers from a lack of objective verification. An approach to this problem is suggested which is based on the comparison of results obtained when different techniques or instruments are applied to the same objects. The application of this approach to scanning versus two-wavelength photometry has been justified by the widely different bases of these two methods. A group of ascites tumor cells stained with gallocyanin-chrome alum was measured successively with both methods and a high degree of proportionality between the two sets of results was found. This suggests that the two methods measure the same quality of the cells within a standard deviation of 3.39 per cent. This degree of correlation is a verification of the accuracy of both of the methods and shows that either one is suitable for resolving differences in stain content between cell nuclei of the order of 10 per cent.

Entities:  

Keywords:  SPECTROPHOTOMETRY; STAINS AND STAINING

Mesh:

Substances:

Year:  1958        PMID: 13610933      PMCID: PMC2224519          DOI: 10.1083/jcb.4.6.707

Source DB:  PubMed          Journal:  J Biophys Biochem Cytol        ISSN: 0095-9901


  5 in total

1.  Changes in nuclear DNA in normal and ascites tumor cells.

Authors:  B M RICHARDS; P M WALKER; E M DEELEY
Journal:  Ann N Y Acad Sci       Date:  1956-03-14       Impact factor: 5.691

2.  Cell crushing: a technique for greatly reducing errors in microspectrometry.

Authors:  H G DAVIES; M H WILKINS; R G BODDY
Journal:  Exp Cell Res       Date:  1954-05       Impact factor: 3.905

3.  Absorption microphotometry of irregular-shaped objects.

Authors:  K PATAU
Journal:  Chromosoma       Date:  1952       Impact factor: 4.316

4.  The distributional error in microspectrophotometry.

Authors:  L ORNSTEIN
Journal:  Lab Invest       Date:  1952       Impact factor: 5.662

5.  The two-wavelength method of microspectrophotometry. I. A microspectrophotometer and tests on model systems.

Authors:  M L MENDELSOHN
Journal:  J Biophys Biochem Cytol       Date:  1958-07-25
  5 in total
  3 in total

1.  A simple scanning cytophotometer.

Authors:  M T JANSEN
Journal:  Z Zellforch Microsk Anat Histochem       Date:  1961

2.  Principles and methods for the quantitative determination of Feulegen stained DNA with the television texture analysis system (TAS).

Authors:  P Bachmann; K Hinrichsen
Journal:  Histochemistry       Date:  1979-02-26

3.  The two-wavelength method of microspectrophotometry. IV. A new solution.

Authors:  M L MENDELSOHN
Journal:  J Biophys Biochem Cytol       Date:  1961-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.