Literature DB >> 1343214

Computed tomography with monochromatic x rays.

F A Dilmanian1.   

Abstract

Recent advances in the development of synchrotron facilities that provide high-energy and high-flux x-ray beams allow the use of monochromatic x rays at a < 0.5% energy bandwidth (i.e. energy width of < 500 eV at 100 keV) for computed tomography (CT) of humans. Such CT systems will consist of a fixed, horizontal, low-divergence fan beam and a seated subject rotating about a vertical axis. Compared to conventional CT, the new system should significantly improve contrast resolution of the image and provide better image quantification because of its lack of beam-hardening effects and its efficient implementation of energy-selective imaging methods such as dual-photon absorptiometry and K-edge subtraction with high-atomic-number (high-Z) contrast-enhancement elements. Further, the nearly parallel synchrotron x-ray beam geometry minimizes patient-to-detector scattering when the detector is positioned far from the patient. The design considerations and the expected performance of monochromatic CT are described, in particular those of the CT being developed at the National Synchrotron Light Source. The potential applications of the method in neuroradiology, cardiac and vascular imaging, bone densitometry, lung imaging, and radiotherapy are discussed. The future of monochromatic CT in research and in clinical diagnostics is also reviewed, as are the prospects for development of compact sources of x rays with narrow-energy bandwidths.

Entities:  

Mesh:

Year:  1992        PMID: 1343214

Source DB:  PubMed          Journal:  Am J Physiol Imaging        ISSN: 0885-8276


  5 in total

1.  Metal artefact reduction in gemstone spectral imaging dual-energy CT with and without metal artefact reduction software.

Authors:  Young Han Lee; Kwan Kyu Park; Ho-Taek Song; Sungjun Kim; Jin-Suck Suh
Journal:  Eur Radiol       Date:  2012-02-04       Impact factor: 5.315

2.  [CT spectral curve in differentiating spinal tumor metastasis and infections].

Authors:  Y Yuan; N Lang; H S Yuan
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2020-10-19

3.  Rapid-kilovoltage-switching dual-energy computed tomography (CT) for differentiating spinal osteolytic metastases from spinal infections.

Authors:  Yuan Yuan; Ning Lang; Huishu Yuan
Journal:  Quant Imaging Med Surg       Date:  2021-02

4.  Renal cyst pseudoenhancement: intraindividual comparison between virtual monochromatic spectral images and conventional polychromatic 120-kVp images obtained during the same CT examination and comparisons among images reconstructed using filtered back projection, adaptive statistical iterative reconstruction, and model-based iterative reconstruction.

Authors:  Yoshitake Yamada; Minoru Yamada; Koichi Sugisawa; Hirotaka Akita; Eisuke Shiomi; Takayuki Abe; Shigeo Okuda; Masahiro Jinzaki
Journal:  Medicine (Baltimore)       Date:  2015-04       Impact factor: 1.889

5.  Going beyond histology. Synchrotron micro-computed tomography as a methodology for biological tissue characterization: from tissue morphology to individual cells.

Authors:  Rolf Zehbe; Astrid Haibel; Heinrich Riesemeier; Ulrich Gross; C James Kirkpatrick; Helmut Schubert; Christoph Brochhausen
Journal:  J R Soc Interface       Date:  2009-03-25       Impact factor: 4.118

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.