Literature DB >> 1341883

Experimental embolic capture by asymmetric Greenfield filters.

L J Greenfield1, M C Proctor.   

Abstract

An uncommon complication of percutaneous insertion of the titanium Greenfield filter is angulation at discharge with clustering of the limbs to one side of the vena cava. Potential adverse effects of this asymmetry were tested in a perfusion system with cadaver venae cavae. The stainless-steel Greenfield filter (SGF) was compared with the modified-hook titanium model (TGF-MH) and a percutaneous modified-hook model of the SGF (SGF-MH) with flexible plastic emboli in four sizes and varied sequences. There were 458 runs comprised of 2203 embolic events, with an overall successful capture rate of 81% despite tilting, asymmetry, and accelerated flow rates from 1.0 to 2.5 L/min. Significant differences were observed in vena cava with diameters greater than 22 mm where capture rate was 76% as opposed to 86% in venae cavae less than 22 mm (p = 0.01). Larger emboli (8 x 25 mm and 8 x 100 mm) were trapped uniformly, whereas smaller emboli (5 x 10 mm) had 59% capture (p = 0.001). Similarly, the capture rate was less when smaller emboli were released before the larger ones (71% vs 87%; p = 0.001). Capture in small versus large venae cavae was not significantly different for the SGF (75%) or TGF-MH (84% vs 87%) but differed for the SGF-MH (98% vs 67%; p less than 0.001). Logistic regression was used to develop a mathematic model for interaction of the variables and determined two first-order interactions: caval size and limb position and caval size and type of filter.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1992        PMID: 1341883

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  3 in total

1.  Strut interlocking of titanium Greenfield vena cava filters and its effect on clot capturing: an in vitro study.

Authors:  C D Korbin; R J Van Allan; R T Andrews; M D Katz; G P Teitelbaum
Journal:  Cardiovasc Intervent Radiol       Date:  1994 Jul-Aug       Impact factor: 2.740

2.  Inferior vena cava filters.

Authors:  Thomas B Kinney
Journal:  Semin Intervent Radiol       Date:  2006-09       Impact factor: 1.513

3.  Limitations of using synthetic blood clots for measuring in vitro clot capture efficiency of inferior vena cava filters.

Authors:  Ronald A Robinson; Luke H Herbertson; Srilekha Sarkar Das; Richard A Malinauskas; William F Pritchard; Laurence W Grossman
Journal:  Med Devices (Auckl)       Date:  2013-05-10
  3 in total