Literature DB >> 1329183

A simplified high-performance liquid chromatographic method for determination of vitamin D3, 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3 in human serum.

L Aksnes1.   

Abstract

Measurement of the serum level of 25-hydroxyvitamin D is the most useful parameter in evaluating vitamin D status. The serum level of vitamin D is a useful parameter in studying short time effects after exposure to ultraviolet light and absorption of the vitamin after oral administration. A method for simultaneous determinations of vitamin D3 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3 is described. Serum or plasma was extracted by methanol-isopropanol (90:10, v/v) and hexane. The hexane layer was injected in to a reversed-phase (C18) high-performance liquid chromatographic (HPLC) system. 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3 were eluted by methanol-water (85:15, v/v), and vitamin D3 by a linear gradient of methanol-water (85:15) and methanol-isopropanol-water (87.5:10:2.5), and detected by u.v. absorption. This method gave separate determinations of the D2 and D3 forms of 25-hydroxyvitamin D, but owing to an interfering peak the method does not measure vitamin D2. The assay was very sensitive with a detection limit of 5 nmol l-1 for 25-hydroxyvitamin D2 and D3 and vitamin D3 by using 0.5 ml serum or plasma for analysis, so that for low vitamin D3 levels more than 1 ml of serum is desirable.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1329183     DOI: 10.3109/00365519209088782

Source DB:  PubMed          Journal:  Scand J Clin Lab Invest        ISSN: 0036-5513            Impact factor:   1.713


  5 in total

1.  Improving the measurement of 25-hydroxyvitamin D.

Authors:  Andrew M Wootton
Journal:  Clin Biochem Rev       Date:  2005-02

2.  Bone metabolism alteration on antiepileptic drug therapy.

Authors:  Geetha Krishnamoorthy; Sunil Karande; Nilesh Ahire; Lily Mathew; Madhuri Kulkarni
Journal:  Indian J Pediatr       Date:  2009-02-10       Impact factor: 1.967

3.  Vitamin D induces increased systolic arterial pressure via vascular reactivity and mechanical properties.

Authors:  Priscila Portugal Dos Santos; Bruna Paola Murino Rafacho; Andréa de Freitas Gonçalves; Rodrigo Gibin Jaldin; Thiago Bruder do Nascimento; Marcondes Alves Barbosa Silva; Stêfany Bruno Assis Cau; Meliza Goi Roscani; Paula Schimdt Azevedo; Marcos Ferreira Minicucci; Rita de Cássia Tostes; Leonardo Antonio Memede Zornoff; Sergio Alberto Rupp de Paiva
Journal:  PLoS One       Date:  2014-06-12       Impact factor: 3.240

4.  The relationship of serum vitamin D and Zinc in a nationally representative sample of Iranian children and adolescents: The CASPIAN-III study.

Authors:  Behzad Shams; Elnaz Afshari; Mohammadhasan Tajadini; Mojtaba Keikha; Mostafa Qorbani; Ramin Heshmat; Mohammad Esmaeil Motlagh; Roya Kelishadi
Journal:  Med J Islam Repub Iran       Date:  2016-10-18

5.  Study of the Vitamin D Levels in Patients Referred to Clinical Laboratories in Mashhad in 2015 and their Relationship with the Patients' Lipid Profiles.

Authors:  Ali Akbar Shamsian; Seyyed Abdolrahim Rezaee; Majid Rajabiian; Habibolah Taghizadeh Moghaddam; Masumeh Saeidi; Abbas Bahreini
Journal:  Electron Physician       Date:  2016-04-25
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.