| Literature DB >> 13284563 |
J H HUMPHREY, J W LIGHTBOWN, M V MUSSETT, W L PERRY.
Abstract
The first attempt to set up an international standard for oxytetracycline, using oxytetracycline hydrochloride, failed because of difficulties in obtaining a preparation whose moisture content was uniform after distribution into ampoules. A preparation of dihydrate of oxytetracycline base was obtained instead, and was compared in an international collaborative assay with a sample of oxytetracycline hydrochloride, which was the current working standard of Chas. Pfizer & Co., Inc., USA. The results of the collaborative assay showed that the potency of the dihydrate was uniform, and that it was a suitable preparation for use as the International Standard.Evidence was obtained, however, that the reference preparation at the time of examination was less potent than had been originally supposed, and that it was hydrated. The potency of the proposed international standard was recalculated after allowance for water in the reference preparation, and the resulting biological potency agreed well with that to be expected on the basis of the physicochemical properties of the preparation. It was agreed, therefore, that the recalculated values should be used, and the preparation of oxytetracycline base dihydrate used in the collaborative assay is established as the International Standard for Oxytetracycline with a potency of 900 International Units per mg.Entities:
Keywords: OXYTETRACYCLINE/preparation of
Mesh:
Substances:
Year: 1955 PMID: 13284563 PMCID: PMC2538083
Source DB: PubMed Journal: Bull World Health Organ ISSN: 0042-9686 Impact factor: 9.408