Literature DB >> 1325013

Heparin-coated circuits reduce activation of granulocytes during cardiopulmonary bypass. A clinical study.

J Borowiec1, S Thelin, L Bagge, L Nilsson, P Venge, H E Hansson.   

Abstract

Activated granulocytes release highly active enzymes such as myeloperoxidase and lactoferrin, which can be involved in tissue destruction mediated by oxygen free radicals. Cardiopulmonary bypass has been reported to activate granulocytes. Bypass circuits coated with heparin have been shown to reduce release of granulocyte factors in experimental studies. In the present study, heparin-coated circuits were compared with noncoated circuits. In seven patients undergoing coronary bypass, heparin-coated circuits were used (group HC), and seven served as control patients (group C). In group HC the heparin dose was reduced to 75% (225 IU/kg). Group C had the standard dose of 300 IU/kg. No preoperative differences in myeloperoxidase and lactoferrin were observed between the groups. At the end of bypass in both groups, there was a significant increase of these enzymes (p less than 0.001) followed by a later decrease. In group HC, however, the release of myeloperoxidase was significantly lower than in group C (215 +/- 24 versus 573 +/- 133 micrograms/L, mean +/- standard error of the mean). The release of lactoferrin was significantly lower in group HC than in group C both at the end of cardiopulmonary bypass (659 +/- 79 versus 1448 +/- 121 micrograms/L) and 3 hours after bypass (224 +/- 37 versus 536 +/- 82 micrograms/L). Granulocytes as well as total number of leukocytes continued to increase until 1 hour after bypass (p less than 0.001) and then manifested a slow decrease. It was concluded that the use of heparin-coated circuits reduced the release of granulocyte factors because of lower activation of leukocytes.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1325013

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  4 in total

1.  Thromboresistant cardiopulmonary bypass circuits: room for improvement?

Authors:  Jeffrey A Poynter
Journal:  J Surg Res       Date:  2010-03-19       Impact factor: 2.192

2.  Centrifugal and roller pumps--are there differences in coagulation and fibrinolysis during and after cardiopulmonary bypass?

Authors:  B E Steinbrueckner; U Steigerwald; F Keller; K Neukam; O Elert; J Babin-Ebell
Journal:  Heart Vessels       Date:  1995       Impact factor: 2.037

3.  Changes in coagulation and fibrinolytic parameters caused by extracorporeal circulation.

Authors:  R Grossmann; J Babin-Ebell; M Misoph; S Schwender; K Neukam; T Hickethier; O Elert; F Keller
Journal:  Heart Vessels       Date:  1996       Impact factor: 2.037

4.  Prolonged granulocyte activation, as well as hypoxanthine and free radical production after open heart surgery in children.

Authors:  E J Pesonen; R Korpela; M Leijala; H Sairanen; O M Pitkänen; K O Raivio; P Venge; S Andersson
Journal:  Intensive Care Med       Date:  1996-05       Impact factor: 17.440

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.