A neuromuscular monitoring system based on a personal computer.

D A White1, M Hull.   

Abstract

We have developed a computerized neuromuscular monitoring system (NMMS) using commercially available subsystems, i.e., computer equipment, clinical nerve stimulator, force transducer, and strip-chart recorder. This NMMS was developed for acquisition and analysis of data for research and teaching purposes. Computer analysis of the muscle response to stimulation allows graphic and numeric presentation of the twitch response and calculated ratios. Since the system can store and recall data, research data can be accessed for analysis and graphic presentation. An IBM PC/AT computer is used as the central controller and data processor. The computer controls timing of the nerve stimulator output, initiates data acquisition, and adjusts the paper speed of the strip chart recorder. The data processing functions include establishing control response values (when no neuromuscular blockade is present), displaying force versus time and calculated data graphically and numerically, and storing these data for further analysis. The general purpose nature of the computer and strip chart recording equipment allow modification of the system primarily by changes in software. For example, new patterns of nerve stimulation, such as the posttetanic count, can be programmed into the computer system along with appropriate data display and analysis routines. The NMMS has functioned well in the operating room environment. We have had no episodes of electrocautery interference with the computer functions. The automated features have enhanced the utility of the NMMS.(ABSTRACT TRUNCATED AT 250 WORDS)

Mesh:

Year:  1992        PMID: 1322977     DOI: 10.1007/bf01616783

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  5 in total

1.  Microcomputer system for the analysis of muscle function.

Authors:  S J McLaughlin; S T Chan; D Ford; S J Neame; H A Dudley
Journal:  J Biomed Eng       Date:  1987-01

2.  Evaluation of recovery from nondepolarizing neuromuscular block, using a digital neuromuscular transmission analyzer: preliminary report.

Authors:  H H Ali; R J Kitz
Journal:  Anesth Analg       Date:  1973 Sep-Oct       Impact factor: 5.108

3.  On-line control of atracurium induced muscle relaxation.

Authors:  H S Bradlow; P C Uys; L B Rametti
Journal:  J Biomed Eng       Date:  1986-01

4.  Posttetanic count (PTC): a new method of evaluating an intense nondepolarizing neuromuscular blockade.

Authors:  J Viby-Mogensen; P Howardy-Hansen; B Chraemmer-Jørgensen; H Ording; J Engbaek; A Nielsen
Journal:  Anesthesiology       Date:  1981-10       Impact factor: 7.892

5.  Clinical evaluation of the Datex 221 neuromuscular transmission monitor for recording posttetanic electromyographic responses.

Authors:  L Gyermek
Journal:  J Clin Anesth       Date:  1990 May-Jun       Impact factor: 9.452

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.