Literature DB >> 1319333

Comparison of technetium-99mC and phytate aerosol in ventilation studies.

P Peltier1, M Bardies, A Chetanneau, J F Chatal.   

Abstract

The image quality obtained with technetium-99mC aerosol (Technegas) was evaluated and compared with that obtained with 99mTc-phytate aerosol generated by a jet nebulizer. Fifty patients underwent ventilation scanning after inhalation of each aerosol (mean interval of 3 days). Four views (anterior, posterior, left and right posterior oblique) were recorded with 200 k precounts. Both sets of images were blindly compared for (i) qualitative evaluation of images, (ii) quantitation of penetration (PI) and heterogeneity (HI) indices and (iii) assessment of ventilation state. Peripheral penetration was the same in 64% of cases, greater with 99mTc-C in 27% and greater with 99mTc-phytate in 9%. The use of 99mTc-C led to fewer and less intense foci of bronchial or gastric activity. The differences for 99mTc-C and 99mTc-phytate, respectively, between mean PI (0.78 vs. 0.70) and HI (15 vs. 18) were not significant. Consideration of all the parameters indicates the overall superiority of 99mTc-C. The final interpretation of the lung ventilation scans was, however, similar with both tracers.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1319333     DOI: 10.1007/bf00177057

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  13 in total

1.  Chronic thromboembolic occlusion of main pulmonary artery does not reduce the lung clearance of 99mTc-DTPA.

Authors:  M Meignan; J Rosso
Journal:  Am Rev Respir Dis       Date:  1989-06

2.  Technegas--a new ventilation agent for lung scanning.

Authors:  W M Burch; P J Sullivan; C J McLaren
Journal:  Nucl Med Commun       Date:  1986-12       Impact factor: 1.690

3.  Increased alveolar epithelial permeability in cigarette smokers.

Authors:  J G Jones; B D Minty; P Lawler; G Hulands; J C Crawley; N Veall
Journal:  Lancet       Date:  1980-01-12       Impact factor: 79.321

4.  Assessment of pulmonary ventilation scans using xenon-127 in the diagnosis of pulmonary embolism.

Authors:  I F Rowe; P J Sleight; J I Gaunt; D N Croft
Journal:  Eur J Nucl Med       Date:  1984

5.  Computation of ventilation-perfusion ratio with Kr-81m in pulmonary embolism.

Authors:  M Meignan; G Simonneau; L Oliveira; A Harf; L Cinotti; J F Cavellier; P Duroux; J C Ansquer; P Galle
Journal:  J Nucl Med       Date:  1984-02       Impact factor: 10.057

6.  Technetium-99m 'pseudogas' for diagnostic studies in the lung.

Authors:  W M Burch; I J Tetley; J L Gras
Journal:  Clin Phys Physiol Meas       Date:  1984-05

7.  Comparison of technetium-99m aerosol and krypton-81m in ventilation studies for the diagnosis of pulmonary embolism.

Authors:  P Peltier; P De Faucal; A Chetanneau; J F Chatal
Journal:  Nucl Med Commun       Date:  1990-09       Impact factor: 1.690

8.  Clearance of inhaled 99mTc DTPA from regions of the lung recently affected by pulmonary embolus.

Authors:  M Buxton-Thomas; T Higenbottam; R Barber; P Wraight
Journal:  Bull Eur Physiopathol Respir       Date:  1986 Jan-Feb

9.  [Ventilation scintigraphy of the lung with 99mTc-DTPA or with 99mTc-sulfur colloid?].

Authors:  D Köhler; G Coates; M Dolovich; M Newhouse; H Matthys
Journal:  Nuklearmedizin       Date:  1983-04       Impact factor: 1.379

10.  Lung ventilation studies with technetium-99m Pseudogas.

Authors:  W M Burch; P J Sullivan; F E Lomas; V A Evans; C J McLaren; R N Arnot
Journal:  J Nucl Med       Date:  1986-06       Impact factor: 10.057

View more
  3 in total

1.  Guidelines for lung scintigraphy in children.

Authors:  Gianclaudio Ciofetta; Amy Piepsz; Isabel Roca; Sybille Fisher; Klaus Hahn; Rune Sixt; Lorenzo Biassoni; Diego De Palma; Pietro Zucchetta
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-09       Impact factor: 9.236

2.  Texture analysis of technegas lung ventilation images.

Authors:  J J Lloyd; C J Taylor; J M James; R S Lawson; R A Shields; H J Testa
Journal:  Med Biol Eng Comput       Date:  1995-01       Impact factor: 2.602

3.  Evaluation of lung clearance of inhaled pertechnegas.

Authors:  S Fanti; G Compagnone; D Pancaldi; R Franchi; C Corbelli; M Marengo; C Onofri; R Galassi; M Levorato; N Monetti
Journal:  Ann Nucl Med       Date:  1996-02       Impact factor: 2.668

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.