Literature DB >> 13129635

Application of video imaging for improvement of patient set-up.

Lennert S Ploeger1, Michel Frenay, Anja Betgen, Josien A de Bois, Kenneth G A Gilhuijs, Marcel van Herk.   

Abstract

BACKGROUND AND
PURPOSE: For radiotherapy of prostate cancer, the patient is usually positioned in the left-right (LR) direction by aligning a single marker on the skin with the projection of a room laser. The aim of this study is to investigate the feasibility of a room-mounted video camera in combination with previously acquired CT data to improve patient set-up along the LR axis.
MATERIAL AND METHODS: The camera was mounted in the treatment room at the caudal side of the patient. For 22 patients with prostate cancer 127 video and portal images were acquired. The set-up error determined by video imaging was found by matching video images with rendered CT images using various techniques. This set-up error was retrospectively compared with the set-up error derived from portal images. It was investigated whether the number of corrections based on portal imaging would decrease if the information obtained from the video images had been used prior to irradiation. Movement of the skin with respect to bone was quantified using an analysis of variance method.
RESULTS: The measurement of the set-up error was most accurate for a technique where outlines and groins on the left and right side of the patient were delineated and aligned individually to the corresponding features extracted from the rendered CT image. The standard deviations (SD) of the systematic and random components of the set-up errors derived from the portal images in the LR direction were 1.5 and 2.1 mm, respectively. When the set-up of the patients was retrospectively adjusted based on the video images, the SD of the systematic and random errors decreased to 1.1 and 1.3 mm, respectively. From retrospective analysis, a reduction of the number of set-up corrections (from nine to six corrections) is expected when the set-up would have been adjusted using the video images. The SD of the magnitude of motion of the skin of the patient with respect to the bony anatomy was estimated to be 1.1 mm.
CONCLUSION: Video imaging is an accurate technique for measuring the set-up of prostate cancer patients in the LR direction. The outline of the patient is a more accurate estimate of the set-up of the bony anatomy than the marker on the patient's abdomen.

Entities:  

Mesh:

Year:  2003        PMID: 13129635     DOI: 10.1016/s0167-8140(03)00230-5

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  5 in total

1.  Target registration errors with surface imaging system in conformal radiotherapy for prostate cancer: study on 19 patients.

Authors:  S Bartoncini; C Fiandra; M G Ruo Redda; S Allis; F Munoz; U Ricardi
Journal:  Radiol Med       Date:  2012-05-14       Impact factor: 3.469

2.  Change in prostate volume during extreme hypo-fractionation analysed with MRI.

Authors:  Adalsteinn Gunnlaugsson; Elisabeth Kjellén; Oskar Hagberg; Camilla Thellenberg-Karlsson; Anders Widmark; Per Nilsson
Journal:  Radiat Oncol       Date:  2014-01-13       Impact factor: 3.481

3.  Comparison of surface matching and target matching for image-guided pelvic radiation therapy for both supine and prone patient positions.

Authors:  Hui Zhao; Brian Wang; Vikren Sarkar; Prema Rassiah-Szegedi; Y Jessica Huang; Martin Szegedi; Long Huang; Victor Gonzalez; Bill Salter
Journal:  J Appl Clin Med Phys       Date:  2016-05-08       Impact factor: 2.102

Review 4.  AAPM task group report 302: Surface-guided radiotherapy.

Authors:  Hania A Al-Hallaq; Laura Cerviño; Alonso N Gutierrez; Amanda Havnen-Smith; Susan A Higgins; Malin Kügele; Laura Padilla; Todd Pawlicki; Nicholas Remmes; Koren Smith; Xiaoli Tang; Wolfgang A Tomé
Journal:  Med Phys       Date:  2022-03-15       Impact factor: 4.506

5.  Reproducibility of patient setup by surface image registration system in conformal radiotherapy of prostate cancer.

Authors:  Marco Krengli; Simone Gaiano; Eleonora Mones; Andrea Ballarè; Debora Beldì; Cesare Bolchini; Gianfranco Loi
Journal:  Radiat Oncol       Date:  2009-02-22       Impact factor: 3.481

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.