Literature DB >> 130843

Effects of implanted Doppler flowmeters on femoral vein autografts.

D D Michie, D F Cowan, C P Cain, C C Bell.   

Abstract

Thirteen femoral vein autografts were placed into the corresponding ipsilateral femoral arteries of 8 mongrel dogs. Cuff-type Doppler (ultrasonic) flowmeters were placed around six of the grafts. None of the vessels thrombosed. Blood flow velocities were measured in all vessels up until the time of sacrifice (mean 95 +/- 5 days after surgery) or accidental death (one dog, 49 days after surgery). The only case of graft failure was attributed to infection at the flowmeter site. With this single exception, the vein grafts exhibited uniformity in histological appearance from dog to dog. These data suggest that implantation of properly designed Doppler flow transducers may have clinical applications. This technique permits continuous or intermittent assessment of blood flow characteristics through a graft without additional trauma or cost to the patient. It is free of the many inherent disadvantages of chronically implanted electromagnetic flowmeters and may negate the need in some instances for followup angiographic studies.

Entities:  

Mesh:

Year:  1976        PMID: 130843      PMCID: PMC1344243          DOI: 10.1097/00000658-197603000-00017

Source DB:  PubMed          Journal:  Ann Surg        ISSN: 0003-4932            Impact factor:   12.969


  16 in total

1.  Infected arterial grafts.

Authors:  G G Jamieson; J A DeWeese; C G Rob
Journal:  Ann Surg       Date:  1975-06       Impact factor: 12.969

2.  Angiography after aortocoronary by-pass grafts.

Authors:  M Amiel; P Mikaeloff; A Rubet; A Clermont
Journal:  J Cardiovasc Surg (Torino)       Date:  1974-03       Impact factor: 1.888

3.  The intimal proliferation in aortic-coronary saphenous vein grafts. Light and electron microscopic studies.

Authors:  W H Kern; G B Dermer; G G Lindesmith
Journal:  Am Heart J       Date:  1972-12       Impact factor: 4.749

4.  Changes in vein grafts following aorto-coronary bypass induced by pressure and ischemia.

Authors:  W R Brody; J C Kosek; W W Angell
Journal:  J Thorac Cardiovasc Surg       Date:  1972-12       Impact factor: 5.209

5.  Radiologic evaluation of coronary artery surgery.

Authors:  H A Baltaxe
Journal:  Circulation       Date:  1973-02       Impact factor: 29.690

6.  Management of infected arterial grafts.

Authors:  F J Wolma; J R Derrick; J McCoy
Journal:  Am J Surg       Date:  1973-12       Impact factor: 2.565

7.  Blood flow measurements in aorto-coronary artery saphenous vein bypass grafts.

Authors:  E A Mazzei; D G Mulder
Journal:  Rev Surg       Date:  1970 Sep-Oct

8.  A historical review of the histology of patent autogenous vein grafts and vein patches.

Authors:  W H Brook
Journal:  J Cardiovasc Surg (Torino)       Date:  1975 Jan-Feb       Impact factor: 1.888

9.  Aortocoronary bypass in the diabetic patient.

Authors:  J J Verska; W J Walker
Journal:  Am J Cardiol       Date:  1975-06       Impact factor: 2.778

10.  The use of free vascular transplants for bridging arterial defects; an historical review with particular reference to histological observations.

Authors:  G SCHLOSS; H B SHUMACKER
Journal:  Yale J Biol Med       Date:  1950-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.