Literature DB >> 1306383

Some flow visualization and laser-Doppler-velocity measurements in a true-to-scale elastic model of a human aortic arch--a new model technique.

D Liepsch1, S Moravec, R Baumgart.   

Abstract

Flow studies were done in an elastic true-to-scale silicone rubber model of an aortic arch to study further hemodynamic influences on atherosclerosis. The model was prepared from a cast of a young woman. A revised model technique was used. The model had a compliance similar to that of the human aortic arch. Velocity measurements were done in the model with a two component laser-Doppler-anemometer in steady and pulsatile flow using a calcium chloride solution with a viscosity of eta = 3.18 mPas and density of rho = 1.28 kg/m3 at 20 degrees C. The time average Reynolds numbers over a whole cycle in the ascending aorta was Re = 1350. The Womersley parameter for pulsatile flow was a = 20. The pulse wave velocity in the ascending aorta was about c = 5.4 m/sec. The secondary flow behavior was discussed for steady and pulsatile flow. Reverse flows were found, especially along the inner radius of the aortic arch in the descending aorta in steady and pulsatile flow and also in small areas of the ascending aorta and at the branches of the aortic arch. The formation of atherosclerotic plaques at preferred local flow regions is discussed.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1306383     DOI: 10.3233/bir-1992-295-615

Source DB:  PubMed          Journal:  Biorheology        ISSN: 0006-355X            Impact factor:   1.875


  5 in total

1.  Detection of pulsatile blood flow cycle in frog microvessels by image velocimetry.

Authors:  S S Singh; M Singh
Journal:  Med Biol Eng Comput       Date:  2002-05       Impact factor: 2.602

2.  Fluid-structure interaction within a layered aortic arch model.

Authors:  Feng Gao; Zhihong Guo; Makoto Sakamoto; Teruo Matsuzawa
Journal:  J Biol Phys       Date:  2006-12-13       Impact factor: 1.365

3.  Stereolithographic vascular replicas from CT scans: choosing treatment strategies, teaching, and research from live patient scan data.

Authors:  Kimberly Knox; Charles W Kerber; Soren A Singel; Michael J Bailey; Steven G Imbesi
Journal:  AJNR Am J Neuroradiol       Date:  2005 Jun-Jul       Impact factor: 3.825

4.  The effect of stents on intra-aneurysmal hemodynamics: in vitro evaluation of a pulsatile sidewall aneurysm using laser Doppler anemometry.

Authors:  Franziska Dorn; Franz Niedermeyer; Andrea Balasso; Dieter Liepsch; Thomas Liebig
Journal:  Neuroradiology       Date:  2010-06-19       Impact factor: 2.804

5.  Stress analysis in a layered aortic arch model under pulsatile blood flow.

Authors:  Feng Gao; Masahiro Watanabe; Teruo Matsuzawa
Journal:  Biomed Eng Online       Date:  2006-04-24       Impact factor: 2.819

  5 in total