Literature DB >> 1304975

Thermal coefficients of paste-paste type pulp capping cements.

Y Fukase1, M Saitoh, M Kaketani, M Ohashi, M Nishiyama.   

Abstract

Thermal coefficients of four kinds of commercially available paste-paste type pulp capping cements were examined. Control reference samples were made of dentin. A thermal coefficient analyzer was used, heating specimens for a few nanoseconds by a xenon flash bulb and measuring thermal changes by using a thermocouple. Thermal coefficients were examined by this non-steady state method. Thermal conductivities of all cements were almost the same or lower than that of dentin. Therefore, when each cement was heated, the penetrating energy was almost the same or lower than that of dentin. The thickness of the cements was converted into that of the dentin by using the obtained thermal conductivity. The 1-mm thickness of the examined cements were equal to between 0.97-mm and 2.10-mm thicknesses of lost dentin. The use of a pulp capping cement provided better pulp protection from thermal stimuli than did the same thickness of dentin.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1304975     DOI: 10.4012/dmj.11.189

Source DB:  PubMed          Journal:  Dent Mater J        ISSN: 0287-4547            Impact factor:   2.102


  5 in total

1.  Heat transfer properties and thermal cure of glass-ionomer dental cements.

Authors:  Lidia Gavic; Kristina Gorseta; Domagoj Glavina; Beata Czarnecka; John W Nicholson
Journal:  J Mater Sci Mater Med       Date:  2015-09-28       Impact factor: 3.896

2.  Model assessing thermal changes during high temperature root canal irrigation.

Authors:  Analise Bartolo; Edmond Koyess; Josette Camilleri; Christopher Micallef
Journal:  Healthc Technol Lett       Date:  2016-08-05

3.  The effect of different pulp capping methods on the intrapulpal temperature when using light-cured procedures.

Authors:  Dayane Oliveira; Mateus-Garcia Rocha; Panagiotis Zoidis; Patricia Pereira; Ana-Paula Ribeiro
Journal:  J Clin Exp Dent       Date:  2022-08-01

4.  Temperature rise during polymerization of different cavity liners and composite resins.

Authors:  Ozcan Karatas; Verda Turel; Yusuf Ziya Bayindir
Journal:  J Conserv Dent       Date:  2015 Nov-Dec

5.  Using 445 nm and 970 nm Lasers on Dental Implants-An In Vitro Study on Change in Temperature and Surface Alterations.

Authors:  Sebastian Malmqvist; Anders Liljeborg; Talat Qadri; Gunnar Johannsen; Annsofi Johannsen
Journal:  Materials (Basel)       Date:  2019-11-27       Impact factor: 3.623