A simulator study of friction in total replacement hip joints.

V Saikko1.   

Abstract

Frictional behaviour of 22 different femoral head-acetabular cup combinations was studied on a new servo-hydraulic microcomputer-controlled hip joint simulator using various flexion-extension angle and superior-inferior load set value waveforms and using distilled water at 37 +/- 1 degrees C as lubricant. Six different head materials were included in the study, whereas all cups were ultra-high molecular weight polyethylene (UHMWPE). Most head-cup combinations studied are commercially available. No distinctly superior joint design can be pointed out, but the frictional behaviour of alumina ceramic against UHMWPE proved overall most favourable (mu min was 0.02), whereas that of non-ion-implanted titanium alloy Ti-6Al-4V against UHMWPE proved strikingly poor (mu max was 0.15). The lowest frictional torque was in 22 mm joints, but frictional torque did not always increase straightforwardly with increasing diameter of the femoral head. The measurements form an extensive comparison between a wide variety of head-cup combinations. The simulator is apparently a useful instrument in the study of frictional behaviour of new designs, materials, surface treatments and coatings that are frequently introduced.

Entities:  

Mesh:

Year:  1992        PMID: 1300112     DOI: 10.1243/PIME_PROC_1992_206_292_02

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  5 in total

1.  Postoperative changes in in vivo measured friction in total hip joint prosthesis during walking.

Authors:  Philipp Damm; Alwina Bender; Georg Bergmann
Journal:  PLoS One       Date:  2015-03-25       Impact factor: 3.240

2.  Influence of hip joint simulator design and mechanics on the wear and creep of metal-on-polyethylene bearings.

Authors:  Murat Ali; Mazen Al-Hajjar; Susan Partridge; Sophie Williams; John Fisher; Louise M Jennings
Journal:  Proc Inst Mech Eng H       Date:  2016-05       Impact factor: 1.617

3.  In vivo measured joint friction in hip implants during walking after a short rest.

Authors:  Philipp Damm; Alwina Bender; Georg Duda; Georg Bergmann
Journal:  PLoS One       Date:  2017-03-28       Impact factor: 3.240

4.  Friction in total hip joint prosthesis measured in vivo during walking.

Authors:  Philipp Damm; Joern Dymke; Robert Ackermann; Alwina Bender; Friedmar Graichen; Andreas Halder; Alexander Beier; Georg Bergmann
Journal:  PLoS One       Date:  2013-11-08       Impact factor: 3.240

5.  Three-dimensional friction measurement during hip simulation.

Authors:  Robert Sonntag; Steffen Braun; Loay Al-Salehi; Joern Reinders; Ulrike Mueller; J Philippe Kretzer
Journal:  PLoS One       Date:  2017-09-08       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.