Abstract

Over a 78-month period from 1983 to 1990 at the Mayo Clinic, 353 patients involving 407 jaws were restored with 1,778 Brånemark system implants supporting prostheses. Complications involved loss of implant anchorage, soft tissue problems, or mechanical problems. The most predominant complication involved soft tissues. There were 152 patients with loaded prostheses who had no complications and 37 with only one occurrence. Those seen in 160 patients with more than one occurrence were all conservatively managed, so that prosthesis use was only permanently discontinued in 4 patients, who returned to the use of a maxillary complete denture.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1299643

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  10 in total

1.  Complete mechanical characterization of an external hexagonal implant connection: in vitro study, 3D FEM, and probabilistic fatigue.

Authors:  María Prados-Privado; Sérgio A Gehrke; Rosa Rojo; Juan Carlos Prados-Frutos
Journal:  Med Biol Eng Comput       Date:  2018-06-11       Impact factor: 2.602

2.  Clinical management and microscopic characterisation of fatigue-induced failure of a dental implant. Case report.

Authors:  S Capodiferro; G Favia; M Scivetti; G De Frenza; R Grassi
Journal:  Head Face Med       Date:  2006-06-22       Impact factor: 2.151

Review 3.  Development of pyogenic granuloma and hemangioma after placement of dental implants: A review of literature.

Authors:  Hashem Motahir Al-Shamiri; Nader Ahmed Alaizari; Sadeq Ali Al-Maweri; Bassel Tarakji
Journal:  J Int Soc Prev Community Dent       Date:  2015 Mar-Apr

Review 4.  A Critical Review of Dental Implant Materials with an Emphasis on Titanium versus Zirconia.

Authors:  Reham B Osman; Michael V Swain
Journal:  Materials (Basel)       Date:  2015-03-05       Impact factor: 3.623

5.  Comparison of the Effect of Three Abutment-implant Connections on Stress Distribution at the Internal Surface of Dental Implants: A Finite Element Analysis.

Authors:  Saeed Raoofi; Maryam Khademi; Reza Amid; Mahdi Kadkhodazadeh; Mohammad Reza Movahhedi
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2013-08-30

Review 6.  Technical complications of implant-causes and management: A comprehensive review.

Authors:  Swati Gupta; Hemant Gupta; Amrit Tandan
Journal:  Natl J Maxillofac Surg       Date:  2015 Jan-Jun

Review 7.  Implant fractures: Rare but not exceptional.

Authors:  Sahitya Sanivarapu; Srinivas Moogla; Rupa Sruthi Kuntcham; Lakshmi Kanth Kolaparthy
Journal:  J Indian Soc Periodontol       Date:  2016 Jan-Feb

Review 8.  Complications in implant dentistry.

Authors:  Ayesha Hanif; Saima Qureshi; Zeeshan Sheikh; Haroon Rashid
Journal:  Eur J Dent       Date:  2017 Jan-Mar

9.  Comparison of implant component fractures in external and internal type: A 12-year retrospective study.

Authors:  Yuseung Yi; Jai-Young Koak; Seong-Kyun Kim; Shin-Jae Lee; Seong-Joo Heo
Journal:  J Adv Prosthodont       Date:  2018-04-18       Impact factor: 1.904

10.  Accuracy of fit of implant-supported bars fabricated on definitive casts made by different dental stones.

Authors:  Ioannis Kioleoglou; Argirios Pissiotis; Michalakis Konstantinos
Journal:  J Clin Exp Dent       Date:  2018-03-01
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.