Literature DB >> 12974937

Emergency stent-graft placement in thoracic aortic dissection and evolving rupture.

Christoph A Nienaber1, Hüseyin Ince, Frank Weber, Tim Rehders, Michael Petzsch, Thomas Meinertz, Dietmar H Koschyk.   

Abstract

BACKGROUND: Even with rapid diagnosis and effective medical treatment mortality in type B aortic dissection with evidence of extraaortic leakage of blood remains high. Considering a mortality rate of 29% to 50% associated with emergency surgical repair, the concept of endovascular stent-graft placement may become a life-saving option in impending or evolving rupture by endovascular sealing of the entry tear and subsequent abortion of leakage.
METHODS: The concept was tested by comparing short-term and 1-year outcomes of 11 patients after emergency endovascular stent-graft placement with historic-matched control patients subjected to conventional therapy. All patients had acute type B dissection complicated by loss of blood into periaortic spaces.
RESULTS: Emergency stent-graft placement was successful without periprocedural morbidity, aborted leakage, and ensured reconstruction of the dissected aorta; at a mean follow-up of 15 +/- 6 months no death had occurred in the stent-graft group whereas four patients had died with conventional treatment (p < 0.05).
CONCLUSION: With appropriate logistics and expertise, type B aortic dissection with leakage and evolving rupture may benefit from nonsurgical reconstruction of the dissected segment by endovascular stent grafts.

Entities:  

Mesh:

Year:  2003        PMID: 12974937     DOI: 10.1046/j.1540-8191.2003.02082.x

Source DB:  PubMed          Journal:  J Card Surg        ISSN: 0886-0440            Impact factor:   1.620


  7 in total

1.  Repair of Acute Type B Aortic Dissection Complicated by Aortic Rupture with Debranching Thoracic Endovascular Aortic Repair and Left Subclavian Artery Occlusion Using Amplatzer Vascular Plug II.

Authors:  Yasunori Iida; Tsutomu Ito; Sachiko Hayashi; Tatsuo Takahashi; Takahiko Misumi; Takashi Hachiya; Hideyuki Shimizu
Journal:  Ann Vasc Dis       Date:  2015-06-15

2.  Thoracic endovascular aortic repair for the treatment of ruptured acute type B aortic dissection.

Authors:  Shuji Chino; Noriyuki Kato; Ken Nakajima; Takashi Hashimoto; Takatoshi Higashigawa; Takafumi Ouchi; Hiroaki Kato; Naoki Yamamoto; Hisato Ito; Yasumi Maze; Toshiya Tokui; Hajime Sakuma
Journal:  Jpn J Radiol       Date:  2019-02-02       Impact factor: 2.374

Review 3.  [Chest injury. Part II: Management of specific injuries].

Authors:  C Waydhas; D Nast-Kolb
Journal:  Unfallchirurg       Date:  2006-10       Impact factor: 1.000

4.  [Endovascular interventions for multiple trauma].

Authors:  C Kinstner; M Funovics
Journal:  Radiologe       Date:  2014-09       Impact factor: 0.635

Review 5.  Emergency stent grafting of type B aortic dissection: technical considerations.

Authors:  Tommaso Lupattelli; Francesco Giuseppe Garaci; Antonio Basile; Andrea Casini; Ilias Dalainas; Daniela Paola Minnella; Roberto Iezzi
Journal:  Emerg Radiol       Date:  2008-08-28

6.  Risk factors of distal segment aortic enlargement after complicated type B aortic dissection.

Authors:  Yu Shen; Simeng Zhang; Guanglang Zhu; Yanqing Chen; Zheng Chen; Zaiping Jing; Qingsheng Lu
Journal:  J Interv Med       Date:  2019-10-23

7.  Detection of Pathological Changes in the Aorta during Thoracic Aortic Aneurysm Progression on Molecular Level.

Authors:  Miroslava Rabajdová; Peter Urban; Ivana Špaková; Artemiou Panagiotis; Michaela Ferenčáková; Dušan Rybár; Nikita Bobrov; František Sabol; Mária Mareková
Journal:  Dis Markers       Date:  2017-10-12       Impact factor: 3.434

  7 in total