Literature DB >> 12974933

Left subclavian artery management in endovascular repair of thoracic aortic aneurysms and aortic dissections.

Kurt Tiesenhausen1, Klaus A Hausegger, Peter Oberwalder, Elisabeth Mahla, Maurice Tomka, Thomas Allmayer, Anneliese Baumann, Michael Hessinger.   

Abstract

PURPOSE: The purpose is to report our experience and revise our previously published results in endovascular repair of short-necked thoracic aortic aneurysms or aortic type B dissections, in which the left subclavian artery (LSA) was occluded by the stent graft intentionally.
METHODS: Seven patients with an aortic type B dissection and three patients who had a thoracic aortic aneurysm were treated endovascularly with stent grafts. In all patients the ostium of the LSA was occluded by the stent graft, only in two patients a primary, prophylactic revascularization of the LSA was performed by transposition to the left common carotid artery (LCA). Two types of stent grafts were used: the Talent (Medtronic) and the Excluder (Gore) stent graft.
RESULTS: In all patients the sealing of the entry tear in aortic dissections and the exclusion of existing thoracic aortic aneurysms were achieved. No immediate neurological deficit or left arm ischemia occurred. Nevertheless, during a mean follow-up of 18 months (2 to 31 months) in three patients a second surgical intervention had to be performed due to subclavian steal syndrome, left arm ischemia, or continuing perfusion of the dissected false aortic channel.
CONCLUSION: Intentional occlusion of the LSA in stent-graft repair of thoracic aortic diseases seems to be a safe procedure. Close follow-up is needed due to arising subclavian steal syndrome, arm ischemia, or persistent perfusion of the false channel via LSA in aortic dissections after patients' discharge, requiring surgical intervention.

Entities:  

Mesh:

Year:  2003        PMID: 12974933     DOI: 10.1046/j.1540-8191.2003.02078.x

Source DB:  PubMed          Journal:  J Card Surg        ISSN: 0886-0440            Impact factor:   1.620


  3 in total

1.  Intentional coverage of the left subclavian artery during endovascular stent graft repair for thoracic aortic disease.

Authors:  R Caronno; G Piffaretti; M Tozzi; C Lomazzi; N Rivolta; P Castelli
Journal:  Surg Endosc       Date:  2006-05-11       Impact factor: 4.584

2.  Electromagnetic navigation for thoracic aortic stent-graft deployment: a pilot study in swine.

Authors:  Nadine Abi-Jaoudeh; Neil Glossop; Michael Dake; William F Pritchard; Alberto Chiesa; Matthew R Dreher; Thomas Tang; John W Karanian; Bradford J Wood
Journal:  J Vasc Interv Radiol       Date:  2010-04-09       Impact factor: 3.464

3.  Management strategies for thoracic stent-graft repair of distal aortic arch lesions: is intentional subclavian artery occlusion a safe procedure?

Authors:  Fabrizio Fanelli; Michael D Dake; Filippo Maria Salvatori; Armando Pucci; Giuseppe Mazzesi; Pierleone Lucatelli; Plinio Rossi; Roberto Passariello
Journal:  Eur Radiol       Date:  2009-05-09       Impact factor: 5.315

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.