Literature DB >> 12970010

High-frequency modulation of heart rate variability during exercise in patients with COPD.

Matthew N Bartels1, Sanja Jelic, Pakkay Ngai, Robert C Basner, Ronald E DeMeersman.   

Abstract

STUDY
OBJECTIVES: To evaluate cardiac autonomic modulation in patients with COPD during peak exercise.
METHODS: Fifty-three patients with COPD (mean FEV(1), 35% predicted [SD, 11% predicted]; mean PaO(2), 68 mm Hg [SD, 11 mm Hg]; mean PaCO(2), 40 mm Hg [SD, 7 mm Hg]; mean age, 61 years [SD, 10 years]; 26 women and 27 men) and 14 healthy control subjects aged 60 years (SD, 8 years) [seven women and seven men] were studied at rest and during ramped bicycle ergometry to their volitional peak. Patients were not receiving autonomic medications other than inhaled beta-agonist agents and/or anticholinergic agents. Control subjects were not receiving any medications. Cardiac autonomic modulation was assessed via time-frequency analysis (Wigner-Ville) of ECG-derived heart rate variability as the power in the low-frequency (LF) band (ie, 0.04 to 0.15 Hz) and the high-frequency (HF) band (ie, > 0.15 to 0.4 Hz) averaged from > 3 min at rest and minutes 2 through 5 of their exercise period.
RESULTS: Patients with COPD had a significantly increased mean, ln-transformed HF band from rest to peak exercise (9.9 ms(2) [SD, 1.4 ms(2)] vs 10.7 ms(2) [SD, 1.4 ms(2)], respectively; p < 0.01), while the HF band was unchanged for the control group (10.7 ms(2) [SD, 1.5 ms(2)] vs 10.4 ms(2) [1.3 ms(2)], respectively; difference not significant). The mean ln-transformed LF band was significantly increased from rest to peak exercise in patients with COPD (10.9 ms(2) [SD, 1.5 ms(2)] vs 11.5 ms(2) [SD, 1.4 ms(2)], respectively; p < 0.01) and in control subjects (10.9 ms(2) [SD, 1.5 ms(2)] vs 11.5 ms(2) [SD, 1.3 ms(2)], respectively; p < 0.01). The mean LF/HF ratio was significantly decreased from rest to peak exercise in patients with COPD (3.1 [SD, 1.5] vs 2.5 [SD, 1.0], respectively; p < 0.01) and was increased in control subjects (1.9 [SD, 0.8] vs 2.4 [1.0], respectively; p < 0.01). When expressed in normalized units ([absolute power of the components]/[total power - very low frequency power] x 100), the HF band was again significantly greater during peak exercise than at rest in the patients with COPD and was unchanged during peak exercise for the control group. Autonomic changes were not significantly correlated with age, gender, body mass index, spirometry, lung volumes, resting gas exchange, or oxygen saturation during exercise.
CONCLUSION: These data suggest that, in contrast to control subjects, the balance of sympathetic to parasympathetic cardiac modulation decreases in patients with COPD during maximal volitional exercise.

Entities:  

Mesh:

Year:  2003        PMID: 12970010     DOI: 10.1378/chest.124.3.863

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  8 in total

1.  Autonomic dysfunction in patients with chronic obstructive pulmonary disease (COPD).

Authors:  Arnoldus J R van Gestel; Joerg Steier
Journal:  J Thorac Dis       Date:  2010-12       Impact factor: 2.895

2.  Baroreceptor sensitivity after Valsalva maneuver in women with chronic obstructive pulmonary disease.

Authors:  Matthew N Bartels; G J Gates; J A Downey; H F Armstrong; R E De Meersman
Journal:  Clin Auton Res       Date:  2012-04-11       Impact factor: 4.435

3.  Exercise capacity and ventilatory response during exercise in COPD patients with and without β blockade.

Authors:  Wilawan Thirapatarapong; Hilary F Armstrong; Matthew N Bartels
Journal:  Lung       Date:  2013-07-23       Impact factor: 2.584

4.  Chronotropic incompetence predicts mortality in severe obstructive pulmonary disease.

Authors:  José González-Costello; Hilary F Armstrong; Ulrich P Jorde; Anna C Bevelaqua; Laurie Letarte; Byron M Thomashow; Matthew N Bartels
Journal:  Respir Physiol Neurobiol       Date:  2013-05-10       Impact factor: 1.931

5.  Are heart rate dynamics in the transition from rest to submaximal exercise related to maximal cardiorespiratory responses in COPD?

Authors:  Adriana Mazzuco; Wladimir Musetti Medeiros; Aline Soares de Souza; Maria Clara Noman Alencar; José Alberto Neder; Audrey Borghi-Silva
Journal:  Braz J Phys Ther       Date:  2017-05-20       Impact factor: 3.377

6.  Analysis of Reasonable Respiratory Efficiency in Tennis Competition and Training Environment Based on Cloud Computing.

Authors:  Honghua Ren; Wang Dan
Journal:  J Healthc Eng       Date:  2022-04-18       Impact factor: 3.822

7.  The relationship between ambient air pollution and heart rate variability differs for individuals with heart and pulmonary disease.

Authors:  Amanda Wheeler; Antonella Zanobetti; Diane R Gold; Joel Schwartz; Peter Stone; Helen H Suh
Journal:  Environ Health Perspect       Date:  2006-04       Impact factor: 9.031

8.  Use of a Wearable Biosensor to Study Heart Rate Variability in Chronic Obstructive Pulmonary Disease and Its Relationship to Disease Severity.

Authors:  Seon-Cheol Park; Narongkorn Saiphoklang; Donghyun Jung; David Gomez; Jonathan E Phillips; Brett A Dolezal; Donald P Tashkin; Igor Barjaktarevic; Christopher B Cooper
Journal:  Sensors (Basel)       Date:  2022-03-15       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.