Literature DB >> 12967796

Artisan toric phakic intraocular lens for the correction of high astigmatism.

Jose L Güell1, Mercedes Vázquez, Francoise Malecaze, Felicidad Manero, Oscar Gris, Fortino Velasco, Helene Hulin, Jaune Pujol.   

Abstract

PURPOSE: To evaluate efficacy, predictability, and safety of Artisan toric phakic intraocular lens (Ophtec, Groningen, The Netherlands) implantation for the correction of astigmatism higher than 2 diopters.
DESIGN: Interventional case series.
METHODS: This prospective study included 27 eyes of 16 patients with a mean preoperative spherical equivalent of -11.78 +/- 6.24 diopters and a mean preoperative astigmatism of -3.43 +/- 0.81. The Artisan phakic intraocular lens was inserted in the anterior chamber through a posterior corneal incision; the technique is similar to the implantation of the classical Artisan lens, but in these cases it is particularly important to secure the lens accurately in the correct axis. The main parameters evaluated in this study were uncorrected visual acuity, best-corrected visual acuity, refraction, and endothelial cell count.
RESULTS: Twelve months after the implantation of the Artisan toric phakic intraocular lens, 62.90% of the eyes were within +/-0.50 diopters. of emmetropia and 96.20% within +/-1.0 diopters. Seventy percent of the eyes gained 1 or more Snellen lines from their preoperative best-corrected visual acuity, and 11.11% lost 1 Snellen line. Mean endothelial cell count increased 2.9%. Mean of the parallel and orthogonal components of cylinder correction were 1.97 diopters and 0.10 diopters, respectively, of the intended cylinder change. The mean of axis alignment error was 10.53 degrees. No serious complications were observed.
CONCLUSION: Artisan toric phakic intraocular lens implantation appears to be a safe and predictable method for the correction of high levels of astigmatism.

Entities:  

Mesh:

Year:  2003        PMID: 12967796     DOI: 10.1016/s0002-9394(03)00295-2

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  11 in total

Review 1.  [Phakic intraocular lenses. Current status and limitations].

Authors:  H B Dick; M Tehrani
Journal:  Ophthalmologe       Date:  2004-03       Impact factor: 1.059

Review 2.  [Intraocular lenses for the correction of refraction errors. Part II. Phakic posterior chamber lenses and refractive lens exchange with posterior chamber lens implantation].

Authors:  T Kohnen; T Kasper; E Terzi
Journal:  Ophthalmologe       Date:  2005-11       Impact factor: 1.059

Review 3.  [Intraocular lenses for the correction of refraction errors. Part 1: phakic anterior chamber lenses].

Authors:  T Kohnen; M Baumeister; M Cichocki
Journal:  Ophthalmologe       Date:  2005-10       Impact factor: 1.059

4.  Five-year follow-up after anterior iris-fixated intraocular lens implantation in phakic eyes to correct high myopia.

Authors:  X Yuan; H Z Ping; W C Hong; D Yin; Z Ting
Journal:  Eye (Lond)       Date:  2011-12-02       Impact factor: 3.775

5.  Comparison of patient outcomes after implantation of Visian toric implantable collamer lens and iris-fixated toric phakic intraocular lens.

Authors:  S Y Lee; H J Kwon; H S Ahn; K Y Seo; E K Kim; T-I Kim
Journal:  Eye (Lond)       Date:  2011-08-19       Impact factor: 3.775

6.  Artisan iris-fixated toric phakic intraocular lens for the correction of high astigmatism after deep anterior lamellar keratoplasty.

Authors:  Madonna G Al-Dreihi; Bachar I Louka; Anas A Anbari
Journal:  Digit J Ophthalmol       Date:  2013-06-14

Review 7.  [Toric phakic intraocular lenses].

Authors:  H B Dick; S E Buchner
Journal:  Ophthalmologe       Date:  2007-12       Impact factor: 1.059

8.  Flexible toric iris claw phakic intraocular lens implantation for myopia and astigmatism.

Authors:  Mohammad Ghoreishi; Reihane Agherian; Ali Reza Peyman; Hamid Feshareki; Mohadeseh Mohammadinia
Journal:  J Ophthalmic Vis Res       Date:  2014-04

9.  Comparison of Toric Foldable Iris-Fixated Phakic Intraocular Lens Implantation and Limbal Relaxing Incisions for Moderate-to-High Myopic Astigmatism.

Authors:  Jeihoon Lee; Hun Lee; David Sung Yong Kang; Jin Young Choi; Eung Kweon Kim; Tae Im Kim
Journal:  Yonsei Med J       Date:  2016-11       Impact factor: 2.759

10.  Comparison between using INTEGRA and manual method in determining axis for intraocular lens implantation: Preliminary retrospective study.

Authors:  Marcin Jaworski; Dorota Wyględowska-Promieńska; Piotr Jaworski; Krzysztof Jaskot; Robert Bieda; Richard Packard
Journal:  Medicine (Baltimore)       Date:  2020-01       Impact factor: 1.889

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.