Literature DB >> 12967078

Effect of the cavity configuration factor on the marginal microleakage of esthetic restorative materials.

Eduardo Batista Franco1, Lawrence Gonzaga Lopes, Rafael Francisco Lia Mondelli, Mário Honorato da Silva e Souza, José Roberto Pereira Lauris.   

Abstract

PURPOSE: To evaluate the effect of the cavity configuration factor (CF) on the marginal microleakage of cervical restorations with four aesthetic restorative materials.
MATERIALS AND METHODS: Conventional cavities, 2.9 mm in diameter and 1.5 mm deep, with CF=2.7 and "saucer"-shaped ones with CF=2 were created in 60 extracted premolars. The following groups were established: G1: Z100/Single Bond, G2: Freedom/Stae, G3: Vitremer/Primer and G4: Durafill/Durafill Bond, following each manufacturer's directions. Thermocycling of the specimens was performed in an aqueous solution of 2% buffered methylene blue, with the temperature varying between 5 to 55 degrees C, for a total of cycles of 60 minutes per day, for 7 days. The specimens were then sectioned and evaluated by two observers using photographs acquired from a stereomicroscope. The values were subjected to Kruskal-Wallis analysis and the Dunn and Wilcoxon test.
RESULTS: The averages of the microleakage scores observed in the conventional and "saucer"-shaped cavities were respectively: G1: 0.66/0.46; G2: 0.92/0.69; G3: 1.8/1.86; G4: 3.54/2.3.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12967078

Source DB:  PubMed          Journal:  Am J Dent        ISSN: 0894-8275            Impact factor:   1.522


  8 in total

1.  A Comparative Evaluation of Microleakage between Resin-Modified Glass Ionomer, Flowable Composite, and Cention-N in Class V Restorations: A Confocal Laser Scanning Microscope Study.

Authors:  Krishnan Venugopal; L Krishnaprasad; Prabath Singh V P; Arjun B Ravi; Kaushik Haridas; Drisya Soman
Journal:  J Pharm Bioallied Sci       Date:  2021-06-05

2.  A comparative evaluation of microleakage of three different newer direct composite resins using a self etching primer in class V cavities: An in vitro study.

Authors:  Mithra N Hegde; Pallavi Vyapaka; Shishir Shetty
Journal:  J Conserv Dent       Date:  2009-10

3.  A comparative evaluation of dentinal hypersensitivity and microleakage associated with composite restorations in cavities preconditioned with air abrasion - An ex vivo study.

Authors:  Ankit Arora; Shashi Rashmi Acharya; Saraswathi M Vidya; Padmaja Sharma
Journal:  Contemp Clin Dent       Date:  2012-07

4.  The Temperature Dependence of Micro-Leakage between Restorative and Pulp Capping Materials by Cu Diffusion.

Authors:  Kamalak H; Mumcu A; Altin S
Journal:  Open Dent J       Date:  2015-03-31

5.  A comparative evaluation of microleakage in class v composite restorations.

Authors:  Sujatha Gopal Sooraparaju; Pavan Kumar Kanumuru; Surya Kumari Nujella; Karthik Roy Konda; K Bala Kasi Reddy; Sivaram Penigalapati
Journal:  Int J Dent       Date:  2014-12-25

6.  Evaluating the Microshear Bond Strength and Microleakage of Flowable Composites Containing Zinc Oxide Nano-particles.

Authors:  Koorosh Teymoornezhad; Homayoun Alaghehmand; Ghazaleh Daryakenari; Soraya Khafri; Mitra Tabari
Journal:  Electron Physician       Date:  2016-11-25

7.  MARGINAL MICROLEAKAGE PROPERTIES OF ACTIVA BIOACTIVE RESTORATIVE AND NANOHYBRID COMPOSITE RESIN USING TWO DIFFERENT ADHESIVES IN NON CARIOUS CERVICAL LESIONS - AN IN VITRO STUDY.

Authors:  M Kaushik; M Yadav
Journal:  J West Afr Coll Surg       Date:  2017 Apr-Jun

8.  Effect of operator variability on microleakage with different adhesive systems.

Authors:  Emel Karaman; A Ruya Yazici; Burak Aksoy; Erdem Karabulut; Gul Ozgunaltay; Berrin Dayangac
Journal:  Eur J Dent       Date:  2013-09
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.