Literature DB >> 12964746

Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS.

B K Matuszewski1, M L Constanzer, C M Chavez-Eng.   

Abstract

In recent years, high-performance liquid chromatography (HPLC) with tandem mass spectrometric (MS/MS) detection has been demonstrated to be a powerful technique for the quantitative determination of drugs and metabolites in biological fluids. However, the common and early perception that utilization of HPLC-MS/MS practically guarantees selectivity is being challenged by a number of reported examples of lack of selectivity due to ion suppression or enhancement caused by the sample matrix and interferences from metabolites. In light of these serious method liabilities, questions about how to develop and validate reliable HPLC-MS/MS methods, especially for supporting long-term human pharmacokinetic studies, are being raised. The central issue is what experiments, in addition to the validation data usually provided for the conventional bioanalytical methods, need to be conducted to confirm HPLC-MS/MS assay selectivity and reliability. The current regulatory requirements include the need for the assessment and elimination of the matrix effect in the bioanalytical methods, but the experimental procedures necessary to assess the matrix effect are not detailed. Practical, experimental approaches for studying, identifying, and eliminating the effect of matrix on the results of quantitative analyses by HPLC-MS/MS are described in this paper. Using as an example a set of validation experiments performed for one of our investigational new drug candidates, the concepts of the quantitative assessment of the "absolute" versus "relative" matrix effect are introduced. In addition, experiments for the determination of, the "true" recovery of analytes using HPLC-MS/MS are described eliminating the uncertainty about the effect of matrix on the determination of this commonly measured method parameter. Determination of the matrix effect allows the assessment of the reliability and selectivity of an existing HPLC-MS/MS method. If the results of these studies are not satisfactory, the parameters determined may provide a guide to what changes in the method need to be made to improve assay selectivity. In addition, a direct comparison of the extent of the matrix effect using two different interfaces (a heated nebulizer, HN, and ion spray, ISP) under otherwise the same sample preparation and chromatographic conditions was made. It was demonstrated that, for the investigational drug under study, the matrix effect was clearly observed when ISP interface was utilized but it was absent when the HN interface was employed.

Entities:  

Mesh:

Year:  2003        PMID: 12964746     DOI: 10.1021/ac020361s

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  460 in total

1.  An LC/MS/MS method for quantitation of chemopreventive sphingadienes in food products and biological samples.

Authors:  J H Suh; A M Makarova; J M Gomez; L A Paul; J D Saba
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2017-07-24       Impact factor: 3.205

2.  Quantification of steroid hormones in low volume plasma and tissue homogenates of fish using LC-MS/MS.

Authors:  Mohammad-Zaman Nouri; Kevin J Kroll; Molly Webb; Nancy D Denslow
Journal:  Gen Comp Endocrinol       Date:  2020-06-27       Impact factor: 2.822

3.  Multiplex ultra-performance liquid chromatography-tandem mass spectrometry method for simultaneous quantification in human plasma of fluconazole, itraconazole, hydroxyitraconazole, posaconazole, voriconazole, voriconazole-N-oxide, anidulafungin, and caspofungin.

Authors:  Laurent Arthur Decosterd; Bertrand Rochat; Benoît Pesse; Thomas Mercier; Frédéric Tissot; Nicolas Widmer; Jacques Bille; Thierry Calandra; Boris Zanolari; Oscar Marchetti
Journal:  Antimicrob Agents Chemother       Date:  2010-09-20       Impact factor: 5.191

4.  Disposition of ketamine and norketamine in hair after a single dose.

Authors:  Ping Xiang; Qiran Sun; Baohua Shen; Min Shen
Journal:  Int J Legal Med       Date:  2010-12-09       Impact factor: 2.686

5.  NHANES monitoring of serum 25-hydroxyvitamin D: a roundtable summary.

Authors:  Elizabeth A Yetley; Christine M Pfeiffer; Rosemary L Schleicher; Karen W Phinney; David A Lacher; Sylvia Christakos; John H Eckfeldt; James C Fleet; George Howard; Andrew N Hoofnagle; Siu L Hui; Gary L Lensmeyer; Joseph Massaro; Munro Peacock; Bernard Rosner; Donald Wiebe; Regan L Bailey; Paul M Coates; Anne C Looker; Christopher Sempos; Clifford L Johnson; Mary Frances Picciano
Journal:  J Nutr       Date:  2010-09-29       Impact factor: 4.798

6.  Aptamer-Conjugated Extracellular Nanovesicles for Targeted Drug Delivery.

Authors:  Yuan Wan; Lixue Wang; Chuandong Zhu; Qin Zheng; Guoxiang Wang; Jinlong Tong; Yuan Fang; Yiqiu Xia; Gong Cheng; Xia He; Si-Yang Zheng
Journal:  Cancer Res       Date:  2017-12-07       Impact factor: 12.701

7.  A validated liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometric method for the quantification of methadone, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), and 2-Ethyl-5-methyl-3,3-diphenylpyroline (EMDP) in human breast milk.

Authors:  Robin E Choo; Lauren M Jansson; Karl Scheidweiler; Marilyn A Huestis
Journal:  J Anal Toxicol       Date:  2007-06       Impact factor: 3.367

8.  A liquid chromatography-mass spectrometry assay for quantification of Exendin[9-39] in human plasma.

Authors:  Maria Lasaosa; Puja Patel; Stephanie Givler; Diva D De León; Steven H Seeholzer
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2013-12-16       Impact factor: 3.205

9.  Determination of crizotinib in human and mouse plasma by liquid chromatography electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS).

Authors:  Michael S Roberts; David C Turner; Alberto Broniscer; Clinton F Stewart
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2014-04-28       Impact factor: 3.205

10.  Cannabinoids in exhaled breath following controlled administration of smoked cannabis.

Authors:  Sarah K Himes; Karl B Scheidweiler; Olof Beck; David A Gorelick; Nathalie A Desrosiers; Marilyn A Huestis
Journal:  Clin Chem       Date:  2013-09-17       Impact factor: 8.327

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.