Literature DB >> 1296338

Simulation of B-scan images from two-dimensional transducer arrays: Part II--Comparisons between linear and two-dimensional phased arrays.

D H Turnbull1, F S Foster.   

Abstract

Two-dimensional (2-D) arrays have been proposed as a solution to the degradation in medical ultrasound image quality occurring as a result of asymmetric focusing properties of linear phased array transducers. The 2-D phased transducer array is also capable of electronically steering the symmetrically focused ultrasound beam throughout a three-dimensional volume. In a companion paper the potential of 2-D transducer arrays for medical imaging has been investigated using simulated B-scan images. In this paper, the advantages of 2-D over linear transducer arrays is demonstrated by simulating images of spherical cysts embedded in a large scattering volume. The large elevation beamwidth in the nearfield of a 5 MHz linear phased transducer array results in a severe reduction in the image contrast measured between a 4 mm diameter cyst and the surrounding scattering media. By employing a 2-D array with symmetric focusing, the contrast between the cyst and surrounding scatterers is significantly improved. The use of additional elements in the elevation direction of a linear array is also investigated. In this case the additional elements are included only to focus, but not to steer the ultrasound beam. Using the contrast characteristics of a 4 mm diameter cyst, it is shown that relatively few elevation elements are required to significantly improve the nearfield imaging capability of the linear array.

Mesh:

Year:  1992        PMID: 1296338     DOI: 10.1177/016173469201400402

Source DB:  PubMed          Journal:  Ultrason Imaging        ISSN: 0161-7346            Impact factor:   1.578


  3 in total

1.  High-resolution real-time three-dimensional acoustic imaging system with a reflector.

Authors:  Hirofumi Taki; Toru Sato
Journal:  J Med Ultrason (2001)       Date:  2007-09-14       Impact factor: 1.314

2.  Sources of image degradation in fundamental and harmonic ultrasound imaging: a nonlinear, full-wave, simulation study.

Authors:  Gianmarco F Pinton; Gregg E Trahey; Jeremy J Dahl
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-06       Impact factor: 2.725

3.  Sources of image degradation in fundamental and harmonic ultrasound imaging using nonlinear, full-wave simulations.

Authors:  Gianmarco F Pinton; Gregg E Trahey; Jeremy J Dahl
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-04       Impact factor: 2.725

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.