Literature DB >> 12957982

Accuracy of emergency physician assessment of left ventricular ejection fraction and central venous pressure using echocardiography.

Marco R Randazzo1, Eric R Snoey, M Andrew Levitt, Kevin Binder.   

Abstract

OBJECTIVES: Emergency department (ED) bedside echocardiography may offer useful information on cardiac function and volume status. The authors evaluated the accuracy of emergency physician (EP) performance of echocardiography in the assessment of left ventricular ejection fraction (LVEF) and central venous pressure (CVP).
METHODS: The authors conducted a cross-sectional observational study at an urban teaching ED, involving a convenience sample of patients presenting to the ED between September 2000 and February 2001. Level III-credentialed EP sonographers who had undergone a three-hour training session in limited echocardiography, focusing on LVEF and CVP measurement, performed echocardiograms. Vital signs and indication for echocardiography were documented on a study data sheet. LVEF was rated as poor (<30%), moderate (30%-55%), or normal (>55%) and an absolute percentage. Central venous pressure categories included low (<5 cm), moderate (5-10 cm), and high (>10 cm). Formal echocardiograms were obtained within a four-hour window on all patients and interpreted by a staff cardiologist. Correlation analysis was performed using the kappa correlation coefficient for LVEF and CVP categories and a Pearson correlation coefficient for LVEF measurement.
RESULTS: A total of 115 patients were assessed for LVEF, and 94 patients had complete information for CVP. Indications for echocardiography included chest pain (45.1%), congestive heart failure (38.1%), dyspnea (5.7%), and endocarditis (10.6%). Results showed a LVEF correlation of r(2) = 0.712 with 86.1% overall agreement. Subgroup analysis revealed the highest agreement (92.3%) between EP and formal echocardiograms within the normal LVEF category, followed by 70.4% agreement in the poor LVEF category and 47.8% in the moderate LVEF category. Central venous pressure measurements resulted in 70.2% overall raw agreement between EP and formal echocardiograms. Subgroup analysis revealed the highest agreement (83.3%) within the high CVP category followed by 66.6% in the moderate and 20% in the low categories.
CONCLUSIONS: Experienced EP sonographers with a small amount of focused additional training in limited bedside echocardiography can assess LVEF accurately in the ED.

Entities:  

Mesh:

Year:  2003        PMID: 12957982     DOI: 10.1111/j.1553-2712.2003.tb00654.x

Source DB:  PubMed          Journal:  Acad Emerg Med        ISSN: 1069-6563            Impact factor:   3.451


  42 in total

1.  Applications of minimally invasive cardiac output monitors.

Authors:  Jahan Porhomayon; Gino Zadeii; Samuel Congello; Nader D Nader
Journal:  Int J Emerg Med       Date:  2012-04-24

Review 2.  Pediatric emergency medicine point-of-care ultrasound: summary of the evidence.

Authors:  Jennifer R Marin; Alyssa M Abo; Alexander C Arroyo; Stephanie J Doniger; Jason W Fischer; Rachel Rempell; Brandi Gary; James F Holmes; David O Kessler; Samuel H F Lam; Marla C Levine; Jason A Levy; Alice Murray; Lorraine Ng; Vicki E Noble; Daniela Ramirez-Schrempp; David C Riley; Turandot Saul; Vaishali Shah; Adam B Sivitz; Ee Tein Tay; David Teng; Lindsey Chaudoin; James W Tsung; Rebecca L Vieira; Yaffa M Vitberg; Resa E Lewiss
Journal:  Crit Ultrasound J       Date:  2016-11-03

3.  Feasibility and acceptability of a structured curriculum in teaching procedural and basic diagnostic ultrasound skills to internal medicine residents.

Authors:  Daniel J Schnobrich; Andrew P J Olson; Alain Broccard; Alisa Duran-Nelson
Journal:  J Grad Med Educ       Date:  2013-09

Review 4.  Bedside US imaging in multiple trauma patients. Part 1: US findings and techniques.

Authors:  Soccorsa Sofia
Journal:  J Ultrasound       Date:  2013-10-31

5.  Cardiac variation of inferior vena cava: new concept in the evaluation of intravascular blood volume.

Authors:  Kensuke Nakamura; Makoto Tomida; Takehiro Ando; Kon Sen; Ryota Inokuchi; Etsuko Kobayashi; Susumu Nakajima; Ichiro Sakuma; Naoki Yahagi
Journal:  J Med Ultrason (2001)       Date:  2013-02-27       Impact factor: 1.314

6.  Focused Ultrasound in the Emergency Department for Patients with Acute Heart Failure.

Authors:  Frances M Russell; Matt Rutz; Peter S Pang
Journal:  Card Fail Rev       Date:  2015-10

7.  Usefulness of inferior vena cava ultrasonography in outpatients with chronic heart failure.

Authors:  Jose Curbelo; Maria Aguilera; Pablo Rodriguez-Cortes; Paloma Gil-Martinez; Carmen Suarez Fernandez
Journal:  Clin Cardiol       Date:  2018-04-17       Impact factor: 2.882

8.  Point-of-care multiorgan ultrasonography for the evaluation of undifferentiated hypotension in the emergency department.

Authors:  G Volpicelli; A Lamorte; M Tullio; L Cardinale; M Giraudo; V Stefanone; E Boero; P Nazerian; R Pozzi; M F Frascisco
Journal:  Intensive Care Med       Date:  2013-04-13       Impact factor: 17.440

9.  Bedside emergency cardiac ultrasound in children.

Authors:  Stephanie J Doniger
Journal:  J Emerg Trauma Shock       Date:  2010-07

Review 10.  Focused critical care echocardiography.

Authors:  Achikam Oren-Grinberg; Daniel Talmor; Samuel M Brown
Journal:  Crit Care Med       Date:  2013-11       Impact factor: 7.598

View more