Literature DB >> 12956347

Glutaraldehyde-induced and formaldehyde-induced allergic contact dermatitis among dental hygienists and assistants.

Scott M Ravis1, Matthew P Shaffer, Christy L Shaffer, Seena Dehkharghani, Seena Dehkhaghani, Donald V Belsito.   

Abstract

BACKGROUND: Research has found that among health care workers, dental personnel are especially likely to have reactions to glutaraldehyde and formaldehyde.
METHODS: The authors conducted patch test evaluations with a voluntary cohort of randomly recruited, healthy dental hygienists, or DHs, and dental assistants, or DAs, and nondental professionals to determine the incidence of glutaraldehyde-induced and formaldehyde-induced allergic contact dermatitis, or ACD; the potential for coreactivity between glutaraldehyde and formaldehyde; and the correlation between training methods in safe handling of sterilizing solutions and the sensitivity to glutaraldehyde and formaldehyde among DHs and DAs.
RESULTS: The researchers enrolled 101 DHs and DAs and 51 nondental professionals in the study. All except one DH/DA subject were female. The dental subjects' mean age was 34.3 +/- standard deviation of 10.7 years; the nondental subjects', 33.8 +/- 11.0 years. DHs and DAs had worked in their profession for a mean of 11.0 +/- 9.3 years. Among the dental professionals, 80 (79.2 percent) had had a known exposure to cold sterilizing solutions, while the remainder were unable to provide a known history of exposure. Eleven (10.9 percent) dental professionals had clear reactions to glutaraldehyde, four (4.0 percent) were questionably allergic to glutaraldehyde, and two (2 percent) were definitively allergic to formaldehyde. One (2 percent) control subject had a reaction to glutaraldehyde, and one other (2 percent) had a reaction to formaldehyde. CONCLUSIONS AND CLINICAL: IMPLICATIONS: The authors found a statistically significant disparity in the rates of glutaraldehyde sensitivity among healthy DHs and DAs versus healthy control subjects (10.9 percent versus 2 percent reactively; P = .02). They found no evidence of cross-reactivity between glutaraldehyde and formaldehyde. The preponderance of reactions among the DHs and DAs suggests that their present safety practices are largely ineffective in protecting against sensitization to glutaraldehyde in sterilizing solutions.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12956347     DOI: 10.14219/jada.archive.2003.0321

Source DB:  PubMed          Journal:  J Am Dent Assoc        ISSN: 0002-8177            Impact factor:   3.634


  2 in total

1.  Comparative efficacy evaluation of disinfectants routinely used in hospital practice: India.

Authors:  Malkit Singh; Rahul Sharma; Pramod K Gupta; Jatinder K Rana; Meera Sharma; Neelam Taneja
Journal:  Indian J Crit Care Med       Date:  2012-07

2.  Exposure of health workers in primary health care to glutaraldehyde.

Authors:  M Angel González Jara; Alfonso Mora Hidalgo; J Carlos Avalos Gulin; Marcos López Albiach; Laura Muñoz Ortiz; Pere Torán Monserrat; Xavier Esteva Ollé
Journal:  J Occup Med Toxicol       Date:  2013-11-01       Impact factor: 2.646

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.