Literature DB >> 12954902

Three-dimensional display modes for CT colonography: conventional 3D virtual colonoscopy versus unfolded cube projection.

Frans M Vos1, Rogier E van Gelder, Iwo W O Serlie, Jasper Florie, C Yung Nio, Afina S Glas, Frits H Post, Roel Truyen, Frans A Gerritsen, Jaap Stoker.   

Abstract

The authors compared a conventional two-directional three-dimensional (3D) display for computed tomography (CT) colonography with an alternative method they developed on the basis of time efficiency and surface visibility. With the conventional technique, 3D ante- and retrograde cine loops were obtained (hereafter, conventional 3D). With the alternative method, six projections were obtained at 90 degrees viewing angles (unfolded cube display). Mean evaluation time per patient with the conventional 3D display was significantly longer than that with the unfolded cube display. With the conventional 3D method, 93.8% of the colon surface came into view; with the unfolded cube method, 99.5% of the colon surface came into view. Sensitivity and specificity were not significantly different between the two methods. Agreements between observers were kappa = 0.605 for conventional 3D display and kappa = 0.692 for unfolded cube display. Consequently, the latter method enhances the 3D endoluminal display with improved time efficiency and higher surface visibility.

Entities:  

Mesh:

Year:  2003        PMID: 12954902     DOI: 10.1148/radiol.2283020846

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  15 in total

Review 1.  Improving the accuracy of CTC interpretation: computer-aided detection.

Authors:  Ronald M Summers
Journal:  Gastrointest Endosc Clin N Am       Date:  2010-04

2.  Comparison of diagnostic accuracy and interpretation times for a standard and an advanced 3D visualisation technique in CT colonography.

Authors:  Thomas Mang; Frank T Kolligs; Claus Schaefer; Maxmilian F Reiser; Anno Graser
Journal:  Eur Radiol       Date:  2010-10-03       Impact factor: 5.315

3.  A comparison of primary two- and three-dimensional methods to review CT colonography.

Authors:  Rogier E van Gelder; Jasper Florie; C Yung Nio; Sebastiaan Jensch; Steven W de Jager; Frans M Vos; Henk W Venema; Joep F Bartelsman; Johannes B Reitsma; Patrick M M Bossuyt; Johan S Laméris; Jaap Stoker
Journal:  Eur Radiol       Date:  2006-11-22       Impact factor: 5.315

4.  CT colonography: comparison of a colon dissection display versus 3D endoluminal view for the detection of polyps.

Authors:  Markus S Juchems; Thorsten R Fleiter; Sandra Pauls; Stefan A Schmidt; Hans-Jürgen Brambs; Andrik J Aschoff
Journal:  Eur Radiol       Date:  2005-06-14       Impact factor: 5.315

Review 5.  CT colonography: an update.

Authors:  Andrik J Aschoff; Andrea S Ernst; Hans-Juergen Brambs; Markus S Juchems
Journal:  Eur Radiol       Date:  2007-09-25       Impact factor: 5.315

6.  [CT colonography: techniques of visualization and findings].

Authors:  J Wessling; W Heindel
Journal:  Radiologe       Date:  2008-02       Impact factor: 0.635

7.  Uni- and bidirectional wide angle CT colonography: effect on missed areas, surface visualization, viewing time and polyp conspicuity.

Authors:  James E East; Brian P Saunders; Darren Boone; David Burling; Steve Halligan; Stuart A Taylor
Journal:  Eur Radiol       Date:  2008-04-15       Impact factor: 5.315

8.  Virtual colonoscopy: Utility, impact and overview.

Authors:  Dhakshina Ganeshan; Khaled M Elsayes; David Vining
Journal:  World J Radiol       Date:  2013-03-28

9.  Does a computer-aided detection algorithm in a second read paradigm enhance the performance of experienced computed tomography colonography readers in a population of increased risk?

Authors:  Ayso H de Vries; Sebastiaan Jensch; Marjolein H Liedenbaum; Jasper Florie; Chung Y Nio; Roel Truyen; Shandra Bipat; Evelien Dekker; Paul Fockens; Lubbertus C Baak; Jaap Stoker
Journal:  Eur Radiol       Date:  2008-11-04       Impact factor: 5.315

10.  Primary uncleansed 2D versus primary electronically cleansed 3D in limited bowel preparation CT-colonography. Is there a difference for novices and experienced readers?

Authors:  Ayso H de Vries; Marjolein H Liedenbaum; Shandra Bipat; Roel Truyen; Iwo W O Serlie; Rutger H Cohen; Saskia G C van Elderen; Anneke Heutinck; Oskar Kesselring; Wouter de Monyé; Lambertus te Strake; Tjeerd Wiersma; Jaap Stoker
Journal:  Eur Radiol       Date:  2009-03-20       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.