Literature DB >> 12954821

Severely impacted valgus proximal humeral fractures. Results of operative treatment.

C Michael Robinson1, Richard S Page.   

Abstract

BACKGROUND: The functional results associated with nonoperative treatment of severely impacted valgus fractures of the proximal part of the humerus are poor, and these injuries are difficult to treat with minimally invasive percutaneous fixation techniques. The aim of this study was to review the functional and radiographic results and complications of a new operative technique in a series of twenty-five patients.
METHODS: Over a two-year period, we treated twenty-nine patients with a severely impacted valgus fracture of the proximal part of the humerus. Three patients were lost to follow-up and one died, leaving twenty-five patients who were available for the study. In all of the fractures, the head-shaft angle had been tilted into > or = 160 degrees of valgus and the greater tuberosity was displaced by >1 cm. All patients were treated with open reduction of the fracture, and the space created behind the humeral head was filled with Norian Skeletal Repair System (SRS) bone substitute. The fractures were stabilized with either screws or buttress plate fixation. Associated rotator cuff tears were repaired. All patients underwent functional outcome assessment with use of the Constant, DASH (Disabilities of the Arm, Shoulder and Hand), and SF-36 (Short Form-36) scores at one year, and twelve patients were followed for two years.
RESULTS: All fractures united within the first year, all reductions were maintained, and no patient had signs of osteonecrosis of the humeral head on the latest follow-up radiographs. At one year, the median Constant score was 80 points and the median DASH score was 22 points. The functional results continued to be satisfactory in the twelve patients who were followed for two years. The results in our series were better than those achieved in studies of nonoperative treatment of similar fracture configurations. There were six clinically relevant complications, although none required a reoperation and all six patients had a satisfactory short-term functional outcome.
CONCLUSIONS: Internal fixation of severely impacted valgus fractures of the proximal part of the humerus, supplemented by Norian SRS bone substitute to fill the proximal humeral metaphyseal defect, produces good early functional and radiographic outcomes. Additional follow-up will be required to assess whether these initially satisfactory outcomes are maintained over the longer term.

Entities:  

Mesh:

Year:  2003        PMID: 12954821     DOI: 10.2106/00004623-200309000-00001

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  32 in total

1.  The relevance of the anatomical basis of fracture for the subsequent treatment of the anterior humeral circumflex artery and the axillary nerve.

Authors:  Yun-Feng Chen; Nai-Feng Zhu; Chang-Qing Zhang; Lei Wang; Hai-Feng Wei; Ye Lu
Journal:  Int Orthop       Date:  2011-12-24       Impact factor: 3.075

2.  Proximal humerus fractures.

Authors:  Mark J Jo; Michael J Gardner
Journal:  Curr Rev Musculoskelet Med       Date:  2012-09

3.  Can the osteosynthesis with locking plates be a better treatment for unstable fractures of the proximal humerus?

Authors:  M A Verdano; E Lunini; A Pellegrini; T Corsini; P Marenghi; F Ceccarelli
Journal:  Musculoskelet Surg       Date:  2013-06-08

4.  Strength recovery after proximal humeral fractures treated with locking plate.

Authors:  M A Verdano; P Baudi; A Pellegrini; E Lunini; D Aliani; G Scita; P Schiavi; C Costantino; F Ceccarelli
Journal:  Musculoskelet Surg       Date:  2014-03-23

5.  Reliability of shoulder abduction strength measure for the Constant-Murley score.

Authors:  Michael Tobias Hirschmann; Björn Wind; Felix Amsler; Thomas Gross
Journal:  Clin Orthop Relat Res       Date:  2009-07-29       Impact factor: 4.176

Review 6.  Biomaterial scaffolds for treating osteoporotic bone.

Authors:  Julie A Sterling; Scott A Guelcher
Journal:  Curr Osteoporos Rep       Date:  2014-03       Impact factor: 5.096

7.  Da Vinci System: clinical experience with complex proximal humerus fractures.

Authors:  Raffaele Russo; Valeria Visconti; Luigi Vernaglia Lombardi; Michele Ciccarelli; Fabio Cautiero
Journal:  Musculoskelet Surg       Date:  2010-05

8.  Valgus impacted proximal humeral fractures and their blood supply after transosseous suturing.

Authors:  Andreas M Panagopoulos; P Dimakopoulos; M Tyllianakis; D Karnabatidis; D Siablis; A X Papadopoulos; E Lambiris; P Kraniotis; G Sakellaropoulos
Journal:  Int Orthop       Date:  2004-08-26       Impact factor: 3.075

9.  [Value of MRI in preoperative diagnostics of proximal humeral fractures compared to CT and conventional radiography].

Authors:  C Voigt; M Ewig; R Vosshenrich; H Lill
Journal:  Unfallchirurg       Date:  2010-05       Impact factor: 1.000

10.  Effect of osteosynthesis, primary hemiarthroplasty, and non-surgical management for displaced four-part fractures of the proximal humerus in elderly: a multi-centre, randomised clinical trial.

Authors:  Stig Brorson; Bo Sanderhoff Olsen; Lars Henrik Frich; Steen Lund Jensen; Hans Viggo Johannsen; Anne Kathrine Sørensen; Asbjørn Hrobjartsson
Journal:  Trials       Date:  2009-07-08       Impact factor: 2.279

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.