Literature DB >> 12950586

Risk of indoor airborne infection transmission estimated from carbon dioxide concentration.

S N Rudnick1, D K Milton.   

Abstract

The Wells-Riley equation, which is used to model the risk of indoor airborne transmission of infectious diseases such as tuberculosis, is sometimes problematic because it assumes steady-state conditions and requires measurement of outdoor air supply rates, which are frequently difficult to measure and often vary with time. We derive an alternative equation that avoids these problems by determining the fraction of inhaled air that has been exhaled previously by someone in the building (rebreathed fraction) using CO2 concentration as a marker for exhaled-breath exposure. We also derive a non-steady-state version of the Wells-Riley equation which is especially useful in poorly ventilated environments when outdoor air supply rates can be assumed constant. Finally, we derive the relationship between the average number of secondary cases infected by each primary case in a building and exposure to exhaled breath and demonstrate that there is likely to be an achievable critical rebreathed fraction of indoor air below which airborne propagation of common respiratory infections and influenza will not occur.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12950586     DOI: 10.1034/j.1600-0668.2003.00189.x

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  106 in total

Review 1.  Transmission and Institutional Infection Control of Tuberculosis.

Authors:  Edward A Nardell
Journal:  Cold Spring Harb Perspect Med       Date:  2015-08-20       Impact factor: 6.915

2.  Infection risk in gyms during physical exercise.

Authors:  Alexandro Andrade; Fábio Hech Dominski; Marcelo Luiz Pereira; Carla Maria de Liz; Giorgio Buonanno
Journal:  Environ Sci Pollut Res Int       Date:  2018-05-07       Impact factor: 4.223

Review 3.  Perspectives on the basic reproductive ratio.

Authors:  J M Heffernan; R J Smith; L M Wahl
Journal:  J R Soc Interface       Date:  2005-09-22       Impact factor: 4.118

4.  Mathematical models for assessing the role of airflow on the risk of airborne infection in hospital wards.

Authors:  Catherine J Noakes; P Andrew Sleigh
Journal:  J R Soc Interface       Date:  2009-10-07       Impact factor: 4.118

5.  Use of a mathematical model to estimate tuberculosis transmission risk in an Internet café.

Authors:  Hiroyuki Furuya; Michiko Nagamine; Tetsu Watanabe
Journal:  Environ Health Prev Med       Date:  2008-11-20       Impact factor: 3.674

Review 6.  Ventilation control for airborne transmission of human exhaled bio-aerosols in buildings.

Authors:  Hua Qian; Xiaohong Zheng
Journal:  J Thorac Dis       Date:  2018-07       Impact factor: 2.895

7.  Modelling respiratory infection control measure effects.

Authors:  C M Liao; S C Chen; C F Chang
Journal:  Epidemiol Infect       Date:  2007-05-16       Impact factor: 2.451

8.  Modeling the role of public transportation in sustaining tuberculosis transmission in South Africa.

Authors:  Jason R Andrews; Carl Morrow; Robin Wood
Journal:  Am J Epidemiol       Date:  2013-02-18       Impact factor: 4.897

9.  Potential for airborne transmission of infection in the waiting areas of healthcare premises: stochastic analysis using a Monte Carlo model.

Authors:  Clive B Beggs; Simon J Shepherd; Kevin G Kerr
Journal:  BMC Infect Dis       Date:  2010-08-20       Impact factor: 3.090

10.  Calculating the potential for within-flight transmission of influenza A (H1N1).

Authors:  Bradley G Wagner; Brian J Coburn; Sally Blower
Journal:  BMC Med       Date:  2009-12-24       Impact factor: 8.775

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.