Evaluation of myocardial performance with conventional single-site ventricular pacing and biventricular pacing in a canine model of atrioventricular block.

Patricio A Frias1, Joel S Corvera, Laura Schmarkey, Margaret Strieper, Robert M Campbell, Jakob Vinten-Johansen.   

Abstract

INTRODUCTION: The aim of this study was to evaluate epicardial biventricular pacing as a means of maintaining synchronous ventricular activation in an acute canine model of AV block with normal ventricular anatomy and function. Chronic single-site ventricular pacing results in dyssynchronous ventricular activation and may contribute to ventricular dysfunction. Biventricular pacing has been used successfully in adult patients with congestive heart failure. METHODS AND
RESULTS: This was an acute study of open chest mongrel dogs (n = 13). ECG, left ventricular (LV), aortic, and pulmonary arterial pressures were measured. LV impedance catheters were used to assess cardiodynamics using instantaneous LV pressure-volume relations (PVR). Following radiofrequency ablation of the AV node, a temporary pacemaker was programmed 10 beats/min above the intrinsic atrial rate, with an AV interval similar to the baseline intrinsic PR interval. The pacing protocol consisted of 5-minute intervals with the following lead configurations: right atrium-right ventricular apex (RA-RVA), RA-LV apex (LVA), and RA-biventricular using combinations of four ventricular sites (RVA, RV outflow tract [RVOT], LVA, LV base [LVB]). RA-RVA was used as the experimental control. LV systolic mechanics, as measured by the slope of the end-systolic (Ees) PVR (ESPVR, mmHg/cc), was statistically greater (P < 0.05) with all modes of biventricular pacing (RA-RVA/LVA 20.0 +/- 2.9, RA-RVA/LVB 18.4 +/- 2.9, RA-RVOT/LVA 15.1 +/- 1.8, RA-RVOT/LVB 17.6 +/- 2.9) compared to single-site ventricular pacing (RA-RVA 12.8 +/- 1.6). Concurrent with this improvement in myocardial performance was a shortening of the QRS duration (RA-RVA 97.7 +/- 2.9 vs RA-RVA/LVA 75.7 +/- 4.9, RA-RVA/LVB 70.3 +/- 4.9, RA-RVOT/LVA 65.3 +/- 4.4, and RA-RVOT/LVB 76.7 +/- 5.9, P < 0.05).
CONCLUSION: In this acute canine model of AV block, QRS duration shortened and LV performance improved with epicardial biventricular pacing compared to standard single-site ventricular pacing.

Entities:  

Mesh:

Year:  2003        PMID: 12950546     DOI: 10.1046/j.1540-8167.2003.02483.x

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  2 in total

1.  Differential Effects of Ventricular Pacing Sites of Contraction Synchrony and Global Cardiac Performance.

Authors:  Mohammed Alhammouri; Hyung Kook Kim; Yasser Mokhtar; Maxime Cannesson; Masaki Tanabe; John Gorcsan; David Schwartzman; Michael R Pinsky
Journal:  Crit Care Shock       Date:  2009-05-01

Review 2.  His Bundle Pacing: A New Frontier in the Treatment of Heart Failure.

Authors:  Nadine Ali; Daniel Keene; Ahran Arnold; Matthew Shun-Shin; Zachary I Whinnett; S M Afzal Sohaib
Journal:  Arrhythm Electrophysiol Rev       Date:  2018-06