Literature DB >> 12949951

Acute ultrastructural changes of the trabecular meshwork after selective laser trabeculoplasty and low power argon laser trabeculoplasty.

Barbara Cvenkel1, Anastazija Hvala, Brigita Drnovsek-Olup, Nina Gale.   

Abstract

BACKGROUND AND OBJECTIVES: To compare the histopathological changes in the human trabecular meshwork after low power argon laser trabeculoplasty (ALT) and selective laser trabeculoplasty (SLT) with a Q-switched, frequency-doubled, neodymium:yttrium-aluminium-garnet (Nd:YAG) laser. STUDY DESIGN/
MATERIALS AND METHODS: In gonioscopically normal trabecular meshwork of three patients awaiting enucleation due to malignant melanoma of the choroid, SLT and ALT were performed 1-5 days prior to enucleation. In each eye, the lower half of trabecular meshwork received SLT, one quadrant low power (460 mW) ALT and one quadrant was left untreated. Specimens were evaluated with light and transmission electron microscopy.
RESULTS: A sharp demarcation line was visible between the laser treated and untreated intact trabecular meshwork after ALT and SLT. Both lasers caused disruption of trabecular beams, but the extent of the damage was smaller after SLT. The collagen component of trabecular beams was mostly amorphous, the long-spacing collagen was scanty after ALT, but more abundant after SLT. In the intertrabecular spaces fragmented cells and tissue debris with only a few pigmented cells were observed. Some endothelial cells were desquamated, but appeared slightly better preserved after SLT than ALT.
CONCLUSIONS: Our ultrastructural comparison of the morphological changes after low power ALT and SLT in patients demonstrated that both lasers caused splitting and fragmentation of the trabecular beams of the trabecular meshwork, but the extent of the damage was smaller and the preservation of long-spacing collagen better after SLT than after ALT. Copyright 2003 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12949951     DOI: 10.1002/lsm.10203

Source DB:  PubMed          Journal:  Lasers Surg Med        ISSN: 0196-8092            Impact factor:   4.025


  27 in total

1.  Selective laser trabeculoplasty induced changes in the thickness of ciliary body and iris evaluated by ultrasound biomicroscopy.

Authors:  Umit Aykan; Ilhami Salcan; Ozlem Yildirim; Dilaver Ersanli
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-11-23       Impact factor: 3.117

2.  A randomised, prospective study comparing selective laser trabeculoplasty with latanoprost for the control of intraocular pressure in ocular hypertension and open angle glaucoma.

Authors:  M Nagar; A Ogunyomade; D P S O'Brart; F Howes; J Marshall
Journal:  Br J Ophthalmol       Date:  2005-11       Impact factor: 4.638

3.  Baseline IOP predicts selective laser trabeculoplasty success at 1 year post-treatment: results from a randomised clinical trial.

Authors:  W G Hodge; K F Damji; W Rock; R Buhrmann; A M Bovell; Y Pan
Journal:  Br J Ophthalmol       Date:  2005-09       Impact factor: 4.638

4.  Selective laser trabeculoplasty: predictive value of early intraocular pressure measurements for success at 3 months.

Authors:  P B Johnson; L J Katz; D J Rhee
Journal:  Br J Ophthalmol       Date:  2006-02-07       Impact factor: 4.638

Review 5.  Selective laser trabeculoplasty (SLT) vs other treatment modalities for glaucoma: systematic review.

Authors:  C McAlinden
Journal:  Eye (Lond)       Date:  2013-12-06       Impact factor: 3.775

6.  [Available laser systems and mechanism of action in laser trabeculoplasty].

Authors:  G R K Kuerzinger; S Eckert
Journal:  Ophthalmologe       Date:  2010-01       Impact factor: 1.059

7.  Selective laser trabeculoplasty in pseudophakic and phakic eyes: a prospective study.

Authors:  Myrjam De Keyser; Maya De Belder; Veva De Groot
Journal:  Int J Ophthalmol       Date:  2017-04-18       Impact factor: 1.779

8.  Impact of laser pulse duration on the reduction of intraocular pressure during selective laser trabeculoplasty.

Authors:  Spela Stunf Pukl; Brigita Drnovšek-Olup
Journal:  Int Ophthalmol       Date:  2016-12-31       Impact factor: 2.031

9.  Efficacy of selective laser trabeculoplasty following incisional glaucoma surgery.

Authors:  Robert Allan Sharpe; Leah L Kammerdiener; David B Williams; Sudeep K Das; Matthew J Nutaitis
Journal:  Int J Ophthalmol       Date:  2018-01-18       Impact factor: 1.779

10.  Update on laser trabeculoplasty.

Authors:  Fathi El Sayyad; Magdi Helal
Journal:  Middle East Afr J Ophthalmol       Date:  2009-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.