Literature DB >> 12948883

Mosquito coil emissions and health implications.

Weili Liu1, Junfeng Zhang, Jamal H Hashim, Juliana Jalaludin, Zailina Hashim, Bernard D Goldstein.   

Abstract

Burning mosquito coils indoors generates smoke that can control mosquitoes effectively. This practice is currently used in numerous households in Asia, Africa, and South America. However, the smoke may contain pollutants of health concern. We conducted the present study to characterize the emissions from four common brands of mosquito coils from China and two common brands from Malaysia. We used mass balance equations to determine emission rates of fine particles (particulate matter < 2.5 microm in diameter; PM(2.5)), polycyclic aromatic hydrocarbons (PAHs), aldehydes, and ketones. Having applied these measured emission rates to predict indoor concentrations under realistic room conditions, we found that pollutant concentrations resulting from burning mosquito coils could substantially exceed health-based air quality standards or guidelines. Under the same combustion conditions, the tested Malaysian mosquito coils generated more measured pollutants than did the tested Chinese mosquito coils. We also identified a large suite of volatile organic compounds, including carcinogens and suspected carcinogens, in the coil smoke. In a set of experiments conducted in a room, we examined the size distribution of particulate matter contained in the coil smoke and found that the particles were ultrafine and fine. The findings from the present study suggest that exposure to the smoke of mosquito coils similar to the tested ones can pose significant acute and chronic health risks. For example, burning one mosquito coil would release the same amount of PM(2.5) mass as burning 75-137 cigarettes. The emission of formaldehyde from burning one coil can be as high as that released from burning 51 cigarettes.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12948883      PMCID: PMC1241646          DOI: 10.1289/ehp.6286

Source DB:  PubMed          Journal:  Environ Health Perspect        ISSN: 0091-6765            Impact factor:   9.031


  15 in total

1.  The effect of cigar smoking on indoor levels of carbon monoxide and particles.

Authors:  N E Klepeis; W R Ott; J L Repace
Journal:  J Expo Anal Environ Epidemiol       Date:  1999 Nov-Dec

2.  Toxic volatile organic compounds in simulated environmental tobacco smoke: emission factors for exposure assessment.

Authors:  J M Daisey; K R Mahanama; A T Hodgson
Journal:  J Expo Anal Environ Epidemiol       Date:  1998 Jul-Sep

3.  Efficacy of mosquito coils containing 0.3% and 0.4% pyrethrins against An.gambiae sensu lato mosquitoes.

Authors:  N Lukwa; S K Chandiwana
Journal:  Cent Afr J Med       Date:  1998-04

4.  Biochemical and cellular changes in bronchoalveolar lavaged samples from rats after inhalation of mosquito-coil smoke.

Authors:  W K Liu; T B Ng; C C Wong
Journal:  Toxicol Lett       Date:  1989-02       Impact factor: 4.372

5.  Aliphatic aldehydes and allethrin in mosquito-coil smoke.

Authors:  J Y Chang; J M Lin
Journal:  Chemosphere       Date:  1998-02       Impact factor: 7.086

6.  Use of benzo[a]pyrene relative abundance ratios to assess exposure to polycyclic aromatic hydrocarbons in the ambient atmosphere in the vicinity of a Söderberg aluminum smelter.

Authors:  E G Sanderson; J P Farant
Journal:  J Air Waste Manag Assoc       Date:  2000-12       Impact factor: 2.235

Review 7.  Indoor air pollution in developing countries: a major environmental and public health challenge.

Authors:  N Bruce; R Perez-Padilla; R Albalak
Journal:  Bull World Health Organ       Date:  2000       Impact factor: 9.408

8.  Some environmental risk factors for childhood asthma: a case-control study.

Authors:  D Fagbule; E E Ekanem
Journal:  Ann Trop Paediatr       Date:  1994

9.  Hydrocarbon emissions and health risks from cookstoves in developing countries.

Authors:  J Zhang; K R Smith
Journal:  J Expo Anal Environ Epidemiol       Date:  1996 Apr-Jun

10.  Levels of exposure and biological monitoring of pyrethroids in spraymen.

Authors:  Z W Zhang; J X Sun; S Y Chen; Y Q Wu; F S He
Journal:  Br J Ind Med       Date:  1991-02
View more
  27 in total

1.  Indoor pesticide application practices and levels in homes of Bangkok Metropolitan Region.

Authors:  Prapat Pentamwa; Nuntakan Kanaratanadilok; Nguyen Thi Kim Oanh
Journal:  Environ Monit Assess       Date:  2010-12-23       Impact factor: 2.513

2.  To coil or not to coil: application practices, perception and efficacy of mosquito coils in a malaria-endemic community in Ghana.

Authors:  Silas W Avicor; Mustafa F F Wajidi; Ebenezer O Owusu
Journal:  Environ Sci Pollut Res Int       Date:  2017-07-20       Impact factor: 4.223

3.  Nasopharyngeal carriage of Klebsiella pneumoniae and other Gram-negative bacilli in pneumonia-prone age groups in Semarang, Indonesia.

Authors:  Helmia Farida; Juliëtte A Severin; M Hussein Gasem; Monique Keuter; Peterhans van den Broek; Peter W M Hermans; Hendro Wahyono; Henri A Verbrugh
Journal:  J Clin Microbiol       Date:  2013-03-13       Impact factor: 5.948

4.  Using charcoal as base material reduces mosquito coil emissions of toxins.

Authors:  L Zhang; Z Jiang; J Tong; Z Wang; Z Han; J Zhang
Journal:  Indoor Air       Date:  2010-04       Impact factor: 5.770

5.  Environmental health risks and benefits of the use of mosquito coils as malaria prevention and control strategy.

Authors:  Jonathan N Hogarh; Thomas P Agyekum; Crentsil Kofi Bempah; Emmanuel D J Owusu-Ansah; Silas W Avicor; Gordon A Awandare; Julius N Fobil; Kwasi Obiri-Danso
Journal:  Malar J       Date:  2018-07-16       Impact factor: 2.979

6.  Attachment rate characteristics of different wide used aerosol sources in indoor air.

Authors:  Mostafa Yuness Abdelfatah Mostafa; Hyam Nazmy Bader Khalaf; Michael Zhukovsky
Journal:  J Environ Health Sci Eng       Date:  2021-04-13

7.  Household inhalants exposure and nasopharyngeal carcinoma risk: a large-scale case-control study in Guangdong, China.

Authors:  Yong-Qiao He; Wen-Qiong Xue; Guo-Ping Shen; Ling-Ling Tang; Yi-Xin Zeng; Wei-Hua Jia
Journal:  BMC Cancer       Date:  2015-12-29       Impact factor: 4.430

8.  Odors and sensations of humidity and dryness in relation to sick building syndrome and home environment in Chongqing, China.

Authors:  Juan Wang; Baizhan Li; Qin Yang; Wei Yu; Han Wang; Dan Norback; Jan Sundell
Journal:  PLoS One       Date:  2013-08-26       Impact factor: 3.240

9.  Chronic obstructive pulmonary disease: Indian guidelines and the road ahead.

Authors:  Parvaiz A Koul
Journal:  Lung India       Date:  2013-07

10.  Application of mosquito repellent coils and associated self-reported health issues in Ghana.

Authors:  Jonathan N Hogarh; Philip Antwi-Agyei; Kwasi Obiri-Danso
Journal:  Malar J       Date:  2016-02-04       Impact factor: 2.979

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.