Literature DB >> 12948121

Analysis of protein adsorption and binding at biosensor polymer interfaces using X-ray photon spectroscopy and scanning electrochemical microscopy.

Andrew Glidle1, Tomoyuki Yasukawa, Charlotte S Hadyoon, Nathalie Anicet, Tomokazu Matsue, Masayuki Nomura, Jon M Cooper.   

Abstract

We describe a method, based on X-ray photoelectron spectroscopy (XPS) measurements, to assess the extent of protein adsorption or binding on a variety of different muTAS and biosensor interfaces. Underpinning this method is the labeling of protein molecules with either iodine- or bromine-containing motifs by using protocols previously developed for radiotracer studies. Using this method, we have examined the adsorption and binding properties of a variety of modified electrodeposited polymer interfaces as well as other materials used in muTAS device fabrication. Using polymer interfaces modified with poly(propylene glycol) (PPG) chains, our results indicate that a chain of at least approximately 30 monomer units is required to inhibit nonspecific adsorption from concentrated protein solutions. The XPS methodology was also used to probe specific binding of avidins and enzyme conjugates thereof to biotinylated and mixed biotin/PPG-modified polymer interfaces. In one example, using competitive binding, it was established that the mode of binding of a peroxidase-streptavidin conjugate to a biotinylated modified polymer interface was primarily via the streptavidin moiety (as opposed to nonspecific binding via the enzyme conjugate). XPS evaluation of nonspecific and specific peroxidase-streptavidin immobilization on various functionalized polymers has guided the design and fabrication of functionalized interdigitated electrodes in a biosensing muTAS device. Subsequent characterization of this device using scanning electrochemical microscopy (SECM) corroborated the adsorption and binding previously inferred from XPS measurements on macroscale electrodes.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12948121     DOI: 10.1021/ac0261653

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

1.  Noncovalent immobilization of streptavidin on in vitro- and in vivo-biotinylated bacterial magnetic particles.

Authors:  Yoshiaki Maeda; Tomoko Yoshino; Masaaki Takahashi; Harumi Ginya; Junko Asahina; Hideji Tajima; Tadashi Matsunaga
Journal:  Appl Environ Microbiol       Date:  2008-06-20       Impact factor: 4.792

2.  Bioelectrochemical switches for the quantitative detection of antibodies directly in whole blood.

Authors:  Alexis Vallée-Bélisle; Francesco Ricci; Takanori Uzawa; Fan Xia; Kevin W Plaxco
Journal:  J Am Chem Soc       Date:  2012-09-10       Impact factor: 15.419

Review 3.  Immobilization techniques for microarray: challenges and applications.

Authors:  Satish Balasaheb Nimse; Keumsoo Song; Mukesh Digambar Sonawane; Danishmalik Rafiq Sayyed; Taisun Kim
Journal:  Sensors (Basel)       Date:  2014-11-25       Impact factor: 3.576

  3 in total