Accounting for high Z shields in brachytherapy using collapsed cone superposition for scatter dose calculation.

Asa K Carlsson Tedgren1, Anders Ahnesjö.   

Abstract

Common clinical brachytherapy treatment planning algorithms perform at best one-dimensional corrections for high Z heterogeneities that will be inaccurate for intermediate energies (60-100 keV). The development of fast methods for a three-dimensional dose calculation to account for high Z materials in this energy range is important, e.g., to fully utilize the potential of patient individualized shields using isotopes such as 241Am and 169Yb. In this work we use the collapsed cone superposition algorithm to calculate the scatter dose contribution around partly lead-shielded point sources at 60, 100, and 350 keV. Methods to scale point kernels for water into kernels for high Z materials are derived. The scaling accounts for scattered photon spectral differences between materials and thus goes beyond the common density scaling approach. Compared to Monte Carlo simulations, the results of our algorithm yield agreements on the unshielded side to within 3% at 350 and 60 keV and to within 7% at 100 keV out to distances of 8 cm from the source. The effect of the shield in the center of the unshielded region is small at 350 keV but significant and occurs at short distances at 100 and 60 keV. At 60 keV, the shield causes a dose reduction of around 10%, 1 cm from the source on the unshielded side. At 100 keV, the reverse effect is seen, the insertion of shields leading to the total dose being increased by about 10% at 1 cm. That one-dimensional algorithms are incapable of predicting these changes shows the importance of accounting for the full three-dimensional geometry in correctly determining the scatter dose contribution.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12945986     DOI: 10.1118/1.1587411

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Treatment planning of a skin-sparing conical breast brachytherapy applicator using conventional brachytherapy software.

Authors:  Yun Yang; Christopher S Melhus; Shirin Sioshansi; Mark J Rivard
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

2.  Current state of the art brachytherapy treatment planning dosimetry algorithms.

Authors:  P Papagiannis; E Pantelis; P Karaiskos
Journal:  Br J Radiol       Date:  2014-07-16       Impact factor: 3.039

Review 3.  Recent developments and best practice in brachytherapy treatment planning.

Authors:  C D Lee
Journal:  Br J Radiol       Date:  2014-06-02       Impact factor: 3.039

Review 4.  A brief look at model-based dose calculation principles, practicalities, and promise.

Authors:  Ron S Sloboda; Hali Morrison; Brie Cawston-Grant; Geetha V Menon
Journal:  J Contemp Brachytherapy       Date:  2017-02-08

5.  Experimental verification of Advanced Collapsed-cone Engine for use with a multichannel vaginal cylinder applicator.

Authors:  Brie Cawston-Grant; Hali Morrison; Geetha Menon; Ron S Sloboda
Journal:  J Appl Clin Med Phys       Date:  2017-03-20       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.